BACKGROUND

The primary goal of this study was to compare the size and depth of the internal jugular vein (IJV) and the subclavian vein (SCV) in infants under general anaesthesia. A secondary goal was to determine the correlation of weight, height, head circumference, and age to the size and depth of these veins.

METHODS

Sixty small infants weighing from 1.4 to 4.5 kg were included. Using ultrasound, the diameters via short-axis (SAX) and long-axis (LAX) views, cross-sectional area (CSA), and depth of the left and right IJV and SCV were measured.

RESULTS

The diameter of the IJV was 7.9% larger on average than that of the SCV as measured via the SAX and LAX views (mean: 3.1 vs 2.9 mm; Wilcoxon's signed-rank test: P<0.01). The CSA of the IJV was 27% larger on average than that of the SCV (mean: 10.2 vs 8.0 mm(2); Wilcoxon's signed-rank test: P<0.01). Seventy-five per cent of the neonates showed a larger CSA of the IJV. The SCV was 8.4% deeper on average from the skin surface than the IJV (mean: 6.4 vs 5.9 mm; Wilcoxon's signed-rank test: P<0.01). There was a significant positive correlation between weight, height, head circumference, and age to the size and depth of the veins (Spearman's rank correlation: P<0.01).

CONCLUSIONS

Because of its most likely larger size, the IJV can be recommended as the better choice for cannulation in comparison with the SCV. However, other factors should also be considered.

摘要

背景

本研究的主要目的是比较全身麻醉下婴儿的颈内静脉(IJV)和锁骨下静脉(SCV)的大小和深度。次要目的是确定体重、身高、头围和年龄与这些静脉的大小和深度的相关性。

方法

纳入 60 名体重 1.4 至 4.5 公斤的小婴儿。使用超声,测量左、右 IJV 和 SCV 的短轴(SAX)和长轴(LAX)视图直径、横截面积(CSA)和深度。

结果

IJV 的直径在 SAX 和 LAX 视图上平均比 SCV 大 7.9%(平均:3.1 与 2.9 毫米;Wilcoxon 符号秩检验:P<0.01)。IJV 的 CSA 平均比 SCV 大 27%(平均:10.2 与 8.0 毫米(2);Wilcoxon 符号秩检验:P<0.01)。75%的新生儿 CSA 较大的 IJV。SCV 从皮肤表面平均比 IJV 深 8.4%(平均:6.4 与 5.9 毫米;Wilcoxon 符号秩检验:P<0.01)。体重、身高、头围和年龄与静脉的大小和深度呈显著正相关(Spearman 秩相关:P<0.01)。

结论

由于其可能更大的尺寸,与 SCV 相比,IJV 可以作为首选的插管部位。然而,还应考虑其他因素。