超声成像在健康非投掷人群中测量肱骨头后倾的可靠性。

Reliability of measuring humeral retroversion using ultrasound imaging in a healthy nonthrowing population.

机构信息

Department of Sport Education, Hokusho University, Ebetsu, Japan.

出版信息

J Sport Rehabil. 2010 May;19(2):149-60. doi: 10.1123/jsr.19.2.149.

Abstract

CONTEXT

Studies have reported the difference in humeral retroversion (HR) between the dominant and nondominant side in throwing athletes. However, there are few data concerning HR for the rest of the population. In addition, the relationship between HR and external (ER) and internal rotation (IR) at 90 degrees shoulder abduction has not been thoroughly investigated.

OBJECTIVES

To investigate the reliability of ultrasound methodology to measure HR. In addition, using ultrasonography, the authors compare HR between the dominant and nondominant sides in healthy adult men and determine the relationship between HR and ER and IR at 90 degrees of shoulder abduction.

DESIGN

Descriptive study.

SETTING

Laboratory.

PARTICIPANTS

Thirty-seven healthy male subjects (age 21.9 +/- 2.4 y, height 172.9 +/- 5.3 cm, weight 66.0 +/- 7.2 kg) with no history of shoulder or elbow injury, recruited from a convenience sample, volunteered for the study.

MAIN OUTCOME MEASURES

Subjects were bilaterally examined for HR, ER, and IR. HR was measured by ultrasonography.

RESULTS

The intrarater reliability of the ultrasound methodology was .91-.98, and the interrater reliability was .97. The HR angle on the dominant side (mean +/- SD: 68.5 degrees +/- 10.0 degrees) was significantly greater than that of the nondominant side (58.0 degrees +/- 8.4 degrees; P < .001). ER on the dominant side was significantly greater than on the nondominant side (P < .001), whereas IR on the dominant side was significantly smaller than on the nondominant side (P < .001). Total arc of motion for the dominant side was not significantly different from that of the nondominant side (P = .335).

CONCLUSION

In the current study, ultrasound methodology to measure HR showed high interrater reliability, as well as high intrarater reliability. In addition, this study indicates that healthy Japanese adult men have side-to-side differences in HR.

摘要

背景

研究报告称,投掷运动员惯用侧和非惯用侧的肱骨后旋(HR)存在差异。然而,关于普通人群的 HR 数据很少。此外,HR 与外旋(ER)和内旋(IR)在 90 度肩外展的关系尚未得到彻底研究。

目的

探讨超声方法测量 HR 的可靠性。此外,作者使用超声检查比较了健康成年男性惯用侧和非惯用侧的 HR,并确定 HR 与 90 度肩外展时 ER 和 IR 的关系。

设计

描述性研究。

地点

实验室。

参与者

37 名健康男性受试者(年龄 21.9±2.4 岁,身高 172.9±5.3cm,体重 66.0±7.2kg),从方便样本中招募,无肩肘受伤史,自愿参加研究。

主要观察指标

双侧检查 HR、ER 和 IR。HR 通过超声检查测量。

结果

超声方法的组内可靠性为.91-.98,组间可靠性为.97。优势侧的 HR 角度(均值±SD:68.5°±10.0°)明显大于非优势侧(58.0°±8.4°;P<.001)。优势侧的 ER 明显大于非优势侧(P<.001),而优势侧的 IR 明显小于非优势侧(P<.001)。优势侧的总活动弧与非优势侧无显著差异(P=.335)。

结论

在本研究中,超声测量 HR 的方法具有较高的组内和组间可靠性。此外,本研究表明,健康的日本成年男性 HR 存在侧别差异。