Abstract

BACKGROUND

Thyroid-stimulating hormone (TSH) measurement plays a major role in the diagnosis of thyroid disorders. Despite the good quality of immunochemical tests measuring TSH levels, the presence of interfering substances can sometimes alter the TSH results.

DESIGN

We reported the case of a 79-year-old man affected by primary autoimmune hypothyroidism hospitalized for pneumonia. A TSH value > 100 mIU L(-1) (reference: 0.44 mIU L(-1)) was found at admission. No signs and symptoms of hypothyroidism were found upon clinical examination and serum concentration of the free thyroxine (FT4) was normal.

RESULTS

Serum treatment in heterophile antibody blocking tubes did not change the TSH result in our assay, while normal levels were found in a different immunoassay method. An abnormal pattern was found in protein electrophoresis at admission, with IgG / j and IgM / k monoclonal bands proved in immunofixation. Interestingly, the disappearance of monoclonal bands was paralleled with a normalization of the TSH value.

CONCLUSIONS

We suggest in this study that the TSH determination might be influenced by the presence of transient paraproteins.

摘要

背景

促甲状腺激素(TSH)的测定在甲状腺疾病的诊断中起着重要作用。尽管测量 TSH 水平的免疫化学检测具有很好的质量,但干扰物质的存在有时会改变 TSH 结果。

设计

我们报告了一例 79 岁的男性患者,患有原发性自身免疫性甲状腺功能减退症,因肺炎住院。入院时发现 TSH 值>100mIU/L(参考值:0.44mIU/L)。临床检查未发现甲状腺功能减退的迹象和症状,血清游离甲状腺素(FT4)浓度正常。

结果

在我们的检测中,血清在异嗜性抗体阻断管中的处理并没有改变 TSH 结果,而在另一种免疫测定方法中则发现正常水平。入院时的蛋白电泳显示出异常模式,免疫固定法证实存在 IgG/ j 和 IgM/ k 单克隆带。有趣的是,TSH 值的正常化与单克隆带的消失相平行。

结论

在本研究中,我们建议 TSH 的测定可能受到短暂性副蛋白的影响。