Department of Radiology, Toyama University, 2630 Sugitani, Toyama 930-0194, Japan.
Neuroradiology. 2011 Mar;53(3):153-8. doi: 10.1007/s00234-010-0711-8. Epub 2010 Jun 20.
To evaluate the hypothesis that flow-sensitive alternating inversion recovery (FAIR) magnetic resonance (MR) imaging can detect retrograde cortical venous drainage (RCVD) in patients with intracranial dural arteriovenous fistula (DAVF).
Seven patients with angiographically confirmed DAVF with RCVD and two DAVF patients without RCVD underwent examinations with conventional MR imaging and FAIR, five of these seven patients with RCVD also underwent examination with dynamic susceptibility contrast (DSC) MR imaging. The ability of FAIR to depict prominent cerebral veins was evaluated, and FAIR was compared with the relative cerebral blood volume (rCBV) maps created with DSC.
In all DAVF patients with RCVD, FAIR clearly showed prominent veins on the surface of the brain in affected hemisphere, and FAIR corresponded well with the areas of increased rCBV. In all DAVF patients without RCVD, FAIR showed no prominent veins.
FAIR can detect RCVD in patients with DAVF.
评估血流敏感交替反转恢复(FAIR)磁共振(MR)成像是否可以检测颅内硬脑膜动静脉瘘(DAVF)患者的逆行性皮质静脉引流(RCVD)。
对 7 例经血管造影证实的有 RCVD 的 DAVF 患者和 2 例无 RCVD 的 DAVF 患者进行了常规 MR 成像和 FAIR 检查,其中 5 例有 RCVD 的患者还进行了动态对比敏感度(DSC)MR 成像检查。评估 FAIR 对明显脑静脉的显示能力,并将 FAIR 与 DSC 生成的相对脑血容量(rCBV)图进行比较。
在所有有 RCVD 的 DAVF 患者中,FAIR 清楚地显示了受累半球脑表面的明显静脉,并且 FAIR 与 rCBV 增加的区域非常吻合。在所有无 RCVD 的 DAVF 患者中,FAIR 未显示明显静脉。
FAIR 可检测 DAVF 患者的 RCVD。