Jeffcote Benjamin, Li Ming-Guo, Barnet-Moorcroft Angela, Wood David, Nivbrant Bo
Fremantle Hospital-Orthopaedic Surgery, Fremantle, Western Australia, Australia.
ANZ J Surg. 2010 Apr;80(4):242-6. doi: 10.1111/j.1445-2197.2009.05040.x.
Hemiarthroplasty is a well-established treatment for displaced subcapital fracture, but controversy exists about the optimal implant type. Bipolar hemiarthroplasty has proposed advantages over unipolar hemiarthroplasty in terms of better clinical results and decreased wear of acetabular cartilage.
This study is a randomized prospective study of 51 patients (52 hips) receiving either bipolar or unipolar hemiarthroplasty for displaced subcapital fractures. The outcome measurements were clinical scores and Roentgen stereophotogrammetric analysis (RSA) analysis to determine the rate of acetabular wear.
Twenty-three patients completed 2-year follow-up. The RSA data demonstrated that there was slightly less acetabular wear by bipolar prostheses than by unipolar. The combined mean three-dimensional wear of the bipolar prostheses was 0.6 mm compared with 1.5 mm for the unipolar prostheses (P= 0.04). The bipolar group generally achieved higher scores in terms of the Harris Hip Score, Western Ontario and McMaster University Index of Osteoarthritis (WOMAC) questionnaire and 6-min walk test. These results were statistically significant at 3 months but not at 12 and 24 months.
This study suggests that while the bipolar prosthesis performs slightly better than the unipolar in terms of acetabular cartilage wear and clinical outcomes, it remains debatable whether the benefits are worth the increased cost of the prosthesis.
半髋关节置换术是治疗移位性股骨头下骨折的一种成熟疗法,但对于最佳植入物类型仍存在争议。双极半髋关节置换术在临床效果更好和髋臼软骨磨损减少方面,相较于单极半髋关节置换术具有优势。
本研究是一项随机前瞻性研究,纳入51例(52髋)因移位性股骨头下骨折接受双极或单极半髋关节置换术的患者。结局测量指标为临床评分和采用X线立体摄影测量分析(RSA)来确定髋臼磨损率。
23例患者完成了2年随访。RSA数据表明,双极假体导致的髋臼磨损略少于单极假体。双极假体的三维联合平均磨损为0.6毫米,而单极假体为1.5毫米(P = 0.04)。在Harris髋关节评分、西安大略和麦克马斯特大学骨关节炎指数(WOMAC)问卷及6分钟步行试验方面,双极组总体得分更高。这些结果在3个月时具有统计学意义,但在12个月和24个月时无统计学意义。
本研究表明,虽然双极假体在髋臼软骨磨损和临床结局方面表现略优于单极假体,但这种益处是否值得假体增加的成本仍存在争议。