Suppr超能文献

序贯吻合与单吻合对冠状动脉旁路移植术中大隐静脉移植物血流特性及中期通畅率的影响。

The impact of sequential versus single anastomoses on flow characteristics and mid-term patency of saphenous vein grafts in coronary bypass grafting.

机构信息

Department of Cardiovascular Surgery, Asan Medical Center, College of Medicine, University of Ulsan, Seoul, Korea.

出版信息

J Thorac Cardiovasc Surg. 2011 Mar;141(3):750-4. doi: 10.1016/j.jtcvs.2010.05.037. Epub 2010 Jul 2.

Abstract

OBJECTIVE

To assess the influence of bypass grafting technique on the flow characteristics and mid-term patency of saphenous vein coronary bypass grafts.

METHODS

In the present study, 309 patients who underwent either sequential (group A, N = 84 grafts) or individual (group B, N = 244 grafts) saphenous vein coronary bypass grafting between February 2002 and September 2007 were investigated. Individual bypassing only was performed in 212 patients, and sequential bypassing only was performed in 78 patients. The remaining 19 patients received both. A total of 436 distal anastomoses were performed with 328 saphenous vein grafts. The intraoperative flow characteristics and the graft patency were assessed with the transit time flow meter and serial multi-detector computed tomography coronary angiograms, respectively.

RESULTS

Group A showed a higher mean flow compared with group B at 49.4 ± 27.4 mL/min versus 37.1 ± 20.1 mL/min, respectively (P = .001). The mean flow increased linearly as the number of anastomoses increased per graft (P < .001). Graft patency at 3 years was 93.3% ± 3.4% in group A and 86.5% ± 3.1% in group B (P = .048). After adjustment for baseline characteristics, group A showed a tendency for superior mid-term patency than group B (hazard ratio 0.362; 95% confidence interval, 0.129-1.017; P = .0538).

CONCLUSIONS

Sequential bypass grafts were associated with higher mean flows and superior mid-term patency compared with individual grafts. These findings suggest the more favorable results of sequential bypass grafting to be attributed to the enhanced flow hemodynamics.

摘要

目的

评估旁路移植技术对大隐静脉冠状动脉旁路移植术血流特性和中期通畅率的影响。

方法

本研究纳入了 2002 年 2 月至 2007 年 9 月间接受序贯(A 组,N=84 支桥)或单支(B 组,N=244 支桥)大隐静脉冠状动脉旁路移植术的 309 例患者。212 例患者仅行单支旁路移植术,78 例患者仅行序贯旁路移植术,19 例患者同时行上述两种术式。共进行了 436 次远端吻合,其中使用了 328 支大隐静脉桥。术中采用瞬时光流测量仪评估血流特性,采用连续多探测器计算机断层扫描冠状动脉造影评估桥血管通畅率。

结果

A 组的平均流量高于 B 组,分别为 49.4±27.4 mL/min 和 37.1±20.1 mL/min(P=0.001)。每支桥血管吻合支数量增加,平均流量呈线性增加(P<0.001)。A 组的桥血管 3 年通畅率为 93.3%±3.4%,B 组为 86.5%±3.1%(P=0.048)。校正基线特征后,A 组的中期通畅率有优于 B 组的趋势(风险比 0.362;95%置信区间,0.129-1.017;P=0.0538)。

结论

与单支桥血管相比,序贯旁路移植术的平均流量更高,中期通畅率更好。这些发现提示,序贯旁路移植术的更有利结果可能归因于增强的血流动力学。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验