Department of Prosthetic Dentistry, Faculty of Dentistry, University of Marmara, Istanbul, Turkey.
Gerodontology. 2012 Mar;29(1):24-9. doi: 10.1111/j.1741-2358.2010.00389.x. Epub 2010 Jun 30.
To compare the effect of different attachment systems with implant-retained overdentures on maximum bite force and muscle activity using electromyography (EMG).
Denture retention and stability is of considerable interest in prosthetic dentistry.
Thirty-five patients were examined: 15 edentulous patients treated with mandibular implant-retained overdentures (MIRO) and maxillary dentures (MCD) (two implant-ball attachment) (BC); 10 edentulous patients treated with MIRO and MCD (four implants-bar attachments) (BRC); 10 patients with edentulous mandibular treated with MIRO and maxillary fixed partial dentures (MFPD) (two implant-ball attachments) (BF). Before implant placement all patients received new dentures. After using these dentures for 3 months the maximum bite force and electrical activity of masseter muscle were measured. Two or four implants were then inserted into the intraforaminal region. After osseointegration periods, patients were treated with MIRO which duplicated their dentures and after three months the measurements were repeated. The data were collected and statistically analysed.
Muscle activity and chewing ability increased in the second period of measurements. Also chewing time was significantly decreased at the first measurements. The highest muscle activity was observed in the group of patients treated with group BF.
The EMG values of the masseter muscle significantly increased when an implant attachments was used in the overdenture.
通过肌电图(EMG)比较不同附着体系统与种植体支持覆盖义齿对最大咬合力和肌肉活动的影响。
义齿的固位和稳定性在修复牙科中是非常重要的。
共检查了 35 名患者:15 名无牙颌患者接受下颌种植体支持覆盖义齿(MIRO)和上颌义齿(MCD)(两个种植体球附着体)(BC)治疗;10 名无牙颌患者接受 MIRO 和 MCD(四个种植体杆附着体)(BRC)治疗;10 名无牙颌下颌患者接受 MIRO 和上颌固定局部义齿(MFPD)(两个种植体球附着体)(BF)治疗。所有患者在植入前都接受了新的义齿。使用这些义齿 3 个月后,测量最大咬合力和咀嚼肌的电活动。然后在翼下颌间隙内植入 2 或 4 个种植体。在骨整合期后,患者接受 MIRO 治疗,复制他们的义齿,3 个月后重复测量。收集并统计分析数据。
在第二次测量期间,肌肉活动和咀嚼能力增加。在第一次测量时,咀嚼时间也显著减少。在接受 BF 组治疗的患者中观察到最高的肌肉活动。
在覆盖义齿中使用种植体附着体时,咀嚼肌的 EMG 值显著增加。