Asenov Deyan Rosenov, Nath Viorel, Telle Aulis, Antweiler Christiane, Walther Leif Erik, Vary Peter, Di Martino Ercole F N
Department of Otorhinolaryngology Head and Neck Surgery DIAKO Hospital Bremen, Germany.
Acta Otolaryngol. 2010 Nov;130(11):1242-8. doi: 10.3109/00016489.2010.492481.
Sonotubometry with perfect sequences (PSEQ) was able to detect eustachian tube (ET) openings in both normal and pathological ears. Impaired ears showed ET openings in almost all cases; however, these proved to be not only less frequent, but also with lower amplitude and shorter duration.
To investigate the function of impaired ET under physiological conditions, using a novel kind of sound stimulus for sonotubometry – the PSEQ.
Twenty otologically healthy subjects (40 normal ears) and 32 patients with ear diseases (40 pathological ears) were examined sonotubometrically using noise signals with an ideally flat spectrum (PSEQ). Dry swallowing, water swallowing, and Toynbee maneuver were used to induce ET openings. Analysis was performed regarding the frequency of occurrence, duration, amplitude, and form of the ET openings.
PSEQ allowed the detection of an ET opening in all 40 normal ears (91% of the performed maneuvers) and in 87.5% of the ears with impaired ET function (but only 47% of the maneuvers). The average amplitude of the openings in healthy ears was 16.86 dB, the average duration was 363 ms. In diseased ears these values were significantly lower: 9.73 dB, p < 0.001 and 280 ms, p < 0.05.
采用完美序列(PSEQ)进行的声管测量法能够检测正常耳和病理耳的咽鼓管(ET)开口。几乎所有病例中,患耳均显示有ET开口;然而,这些开口不仅出现频率较低,而且幅度较小、持续时间较短。
使用一种新型的声管测量声音刺激——PSEQ,研究生理条件下受损ET的功能。
对20名听力正常的受试者(40只正常耳)和32名耳部疾病患者(40只病理耳)使用具有理想平坦频谱的噪声信号(PSEQ)进行声管测量检查。采用干吞咽、水吞咽和陶因比手法诱导ET开口。对ET开口的发生频率、持续时间、幅度和形态进行分析。
PSEQ能够检测到所有40只正常耳中的ET开口(占所执行手法的91%)以及87.5%的ET功能受损耳中的开口(但仅占所执行手法的47%)。健康耳中开口的平均幅度为16.86 dB,平均持续时间为363 ms。患病耳中的这些值显著较低:分别为9.73 dB,p < 0.001和280 ms,p < 0.05。