Hoeft A, Sonntag H, Stephan H, Kettler D
Zentrum Anaesthesiologie, Rettungs- und Intensivmedizin, Universität Göttingen, Germany.
Anesthesiology. 1991 Jul;75(1):49-56. doi: 10.1097/00000542-199107000-00009.
An important guideline for anesthesia in patients with ischemic heart disease is the effect on myocardial oxygen demand. Therefore, this investigation evaluated commonly used myocardial oxygen demand formulas for clinical application. The study was performed on patients undergoing coronary bypass surgery (n = 62). Measurements of standard hemodynamics were obtained before and after induction of anesthesia, as well as during sternotomy and after surgery. Coronary blood flow was determined by the argon wash-in technique. In 15 patients, a left ventricular tip manometer was used to accurately assess the first derivative of left ventricular pressure time course. The following indices of left ventricular oxygen demand were calculated: 1) rate pressure product (RPP); 2) tension time index (TTI); 3) pressure work index (PWI) according to the methods of Rooke; and 4) additive parameter (Eg), according to the methods of Bretschneider. All hemodynamic indices of myocardial oxygen demand showed moderate correlation with myocardial oxygen uptake (MVO2) (RPP: r = 0.77; TTI: r = 0.79; PWI: r = 0.79; Eg: r = 0.71). On the average, PWI and Eg led to an underestimation of MVO2 in patients. The constants of the PWI and Eg formulas, which have been developed based on animal experiments, therefore are not directly applicable to clinical conditions. New constants have been derived for PWI by multiple linear regression analysis of the data in the current investigation.(ABSTRACT TRUNCATED AT 250 WORDS)
缺血性心脏病患者麻醉的一项重要指导原则是对心肌需氧量的影响。因此,本研究评估了常用的心肌需氧量公式在临床中的应用。该研究对接受冠状动脉搭桥手术的患者(n = 62)进行。在麻醉诱导前后、胸骨切开术期间及术后均进行了标准血流动力学测量。冠状动脉血流通过氩气冲洗技术测定。在15例患者中,使用左心室尖部压力计精确评估左心室压力时间过程的一阶导数。计算了以下左心室需氧量指标:1)心率血压乘积(RPP);2)张力时间指数(TTI);3)根据鲁克方法计算的压力作功指数(PWI);4)根据布雷tschneider方法计算的附加参数(Eg)。所有心肌需氧量的血流动力学指标与心肌摄氧量(MVO2)均呈中度相关(RPP:r = 0.77;TTI:r = 0.79;PWI:r = 0.79;Eg:r = 0.71)。平均而言,PWI和Eg导致对患者MVO2的低估。基于动物实验开发的PWI和Eg公式的常数因此不适用于临床情况。通过对本研究数据进行多元线性回归分析,得出了PWI的新常数。(摘要截断于250字)