Suppr超能文献

用于人工尿道括约肌性能评估的测试装置和方法。

Test apparatus and methods for performance evaluation of an artificial urinary sphincter.

作者信息

Allaire M J, Reynolds D B

机构信息

Dept. of Biomedical & Human Factors Engr., Wright State University, Dayton, OH 45435.

出版信息

Biomed Sci Instrum. 1991;27:263-72.

PMID:2065164
Abstract

We have designed, built and tested an experimental apparatus for in vitro performance testing of an artificial urinary sphincter. A simulated urinary tract delivered a simulated urine to either an excised porcine urethra or artificial urethra at a physiologically normal pressure range of 0-93 cm H2O (0-9.12 kPa) and flow rate range of 0-830 ml/min (0-1.38 x 10(-5) m3/s). Inlet urine pressure, sphincter temperatures at several locations, urine flow, differential pressure across the urethra, and linear motion of the sphincter were measured with appropriate transducers and recorded on a PC-based data acquisition system. We conclude that the simulated urinary tract is adequate for testing artificial sphincter performance and that the data acquisition system accurately measures, displays, and records the parameters which indicate system performance.

摘要

我们设计、构建并测试了一种用于人工尿道括约肌体外性能测试的实验装置。一个模拟尿路在生理正常压力范围0 - 93厘米水柱(0 - 9.12千帕)和流速范围0 - 830毫升/分钟(0 - 1.38×10⁻⁵立方米/秒)下,将模拟尿液输送至切除的猪尿道或人工尿道。通过合适的传感器测量入口尿液压力、几个位置的括约肌温度、尿液流量、尿道两端的压差以及括约肌的线性运动,并记录在基于个人电脑的数据采集系统上。我们得出结论,模拟尿路足以用于测试人工括约肌的性能,并且数据采集系统能够准确测量、显示和记录指示系统性能的参数。