Suppr超能文献

奶牛反复接触杂散电压对其活动、应激生理和产奶量及成分的中期影响。

Medium-term effects of repeated exposure to stray voltage on activity, stress physiology, and milk production and composition in dairy cows.

机构信息

AgroParisTech, 16 rue Claude Bernard, 75005 Paris, France.

出版信息

J Dairy Sci. 2010 Aug;93(8):3542-52. doi: 10.3168/jds.2009-2903.

Abstract

The medium-term effects of permanent or random exposure to stray voltage applied to the water trough were evaluated on milk production and stress physiology in lactating dairy cows. Seventy-four Holstein cows were assigned during two 8-wk experimental periods to 1 of 3 treatments. The treatments were permanent exposure to voltage (PERM, 1.8 V, n=23) applied to the water trough, random exposure to voltage (RAND, 1.8 V, 36 h/wk, n=25), and no exposure to voltage (control, n=26). On the first day of voltage exposure, PERM cows had higher activity levels than control cows (9.8+/-2.70 vs. -2.3+/-2.74 14-s periods of movement/h). During the eighth week of exposure, RAND cows had higher activity levels than control cows (4.2+/-3.64 vs. -7.7+/-3.54 14-s periods of movement/h) and higher milk cortisol concentration than PERM cows (0.21+/-0.024 vs. 0.14+/-0.020 ng/mL). No differences were observed between treatments for cortisol response after an ACTH challenge during the seventh week of exposure. No effects of voltage exposure were observed on production traits and daily water intake. There was a transient decrease in milk yield on the second day of exposure in PERM cows (-1.4+/-0.74 kg) and on the third day of exposure in RAND cows (-3.5+/-1.03 kg) compared with control cows. In dairy cows, permanent or random exposure to stray voltage (1.8 V; 3.6 mA) could induce a transient stress response. Moreover, unpredictable voltage exposure could be considered a mild stressor, with slight modifications in stress physiology and activity but no impairment in production in the medium term.

摘要

研究了长期持续或随机接触水槽中杂散电压对泌乳奶牛产奶量和应激生理的影响。在两个 8 周的实验期间,将 74 头荷斯坦奶牛分配到 3 种处理中的 1 种。处理包括:水槽中持续接触电压(PERM,1.8V,n=23)、随机接触电压(RAND,1.8V,36h/周,n=25)和不接触电压(对照组,n=26)。在接触电压的第一天,PERM 奶牛的活动水平高于对照组奶牛(9.8+/-2.70 比-2.3+/-2.74 14 秒的运动周期/小时)。在暴露的第八周,RAND 奶牛的活动水平高于对照组奶牛(4.2+/-3.64 比-7.7+/-3.54 14 秒的运动周期/小时),且牛奶皮质醇浓度高于 PERM 奶牛(0.21+/-0.024 比 0.14+/-0.020 ng/mL)。在暴露的第七周接受 ACTH 挑战后,处理组之间没有观察到皮质醇反应的差异。电压暴露对产奶量和每日水摄入量没有影响。与对照组奶牛相比,PERM 奶牛在接触电压的第二天(-1.4+/-0.74kg)和 RAND 奶牛在接触电压的第三天(-3.5+/-1.03kg)产奶量出现短暂下降。在泌乳奶牛中,长期或随机接触(1.8V;3.6mA)杂散电压可能会引起短暂的应激反应。此外,不可预测的电压暴露可能被视为一种轻度应激源,对应激生理和活动有轻微的影响,但在中期不会对生产造成损害。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验