Department of Physical Chemistry, Swiss Federal Institute of Technology, CH-8092, Zürich, Switzerland.
J Biomol NMR. 1996 Oct;8(3):285-91. doi: 10.1007/BF00410327.
Application of the weak-coupling scheme to restrain the configurations of a molecular system to a set of NOE distance restraints is investigated using two test systems: (i) a 15-atom chain molecule with one distance restraint; and (ii) a protein molecule with hundreds of NOE distance restraints. Atom-atom distance restraining by the weak-coupling technique is possible, but this method does not produce as good results as the penalty function method normally used to maintain NOE distance restraints.