Suppr超能文献

Laparoendoscopic single-site surgery using a 2-mm miniport: initial gynecologic experience performed by a standard trocar and instruments.

作者信息

Chong Gun Oh, Park Nae Yoon, Seong Won Joon, Hong Dae Gy, Lee Yoon Soon

机构信息

Department of Obstetrics and Gynecology, School of Medicine, Kyungpook National University Hospital , Daegu, Korea.

出版信息

J Laparoendosc Adv Surg Tech A. 2010 Sep;20(7):605-8. doi: 10.1089/lap.2010.0031.

Abstract

OBJECTIVES

To evaluate the feasibility, safety, and patients' satisfaction of laparoendoscopic single-site surgery (LESS) with a 2-mm miniport using a standard trocar and instruments.

METHODS

Between November 2008 and October 2009, we performed LESS for benign gynecologic conditions with a 2-mm miniport in 61 patients. Only 1 case was converted to conventional laparoscopic surgery using three ports to perform an appendectomy. The level of satisfaction of the patients was surveyed with five scales ("very satisfied," "satisfied," "not sure," "unsatisfied," and "very unsatisfied").

RESULTS

The mean operative time was 46.6 +/- 20.7 minutes, and the mean blood loss was 8.9 +/- 7.4 mL. The length of the hospital stay postoperatively averaged 1.8 +/- 0.9 days. No complications that required treatment occurred. Among 60 patients, 52 patients (87%) responded to the survey. Thirteen patients (25%) were "very satisfied," 29 patients (56%) were "satisfied," 8 patients (15%) were "not sure," and 2 patients (4%) were "unsatisfied." Forty-two patients (81%) had a positive perception of the surgery. Forty-nine patients (94%) responded that they were satisfied with the cosmetic outcome.

CONCLUSION

LESS with a 2-mm miniport is a feasible and safe treatment modality for benign gynecologic diseases without incurring additional costs. Moreover, the cosmetic results were excellent.