Division of Female Pelvic Medicine and Reconstructive Surgery, Department of Obstetrics and Gynecology, Indianapolis, IN, USA.
Am J Obstet Gynecol. 2010 Nov;203(5):504.e1-5. doi: 10.1016/j.ajog.2010.06.034. Epub 2010 Aug 5.
The purpose of this study was to compare pre- and postoperative pelvic organ prolapse-quantification (POP-Q) and magnetic resonance imaging (MRI) measurements in patients who undergo total Prolift (Ethicon, Inc, Somerville, NJ) colpopexy.
Pre- and postoperative MRI and POP-Q examinations were performed on patients with stage 2 or greater prolapse who underwent the Prolift procedure. MRI measurements were taken at maximum descent. Correlations between changes in MRI and POP-Q measurements were determined.
Ten subjects were enrolled. On MRI, statistically significant changes were seen with cystocele, enterocele, and apex. Statistically significant changes were seen on POP-Q measurements for Aa, Ba, C, Ap, Bp, and GH. Positive correlations were demonstrated between POP-Q and MRI changes. Minimal tissue reaction was seen on MRI.
The Prolift system is effective in the surgical management of pelvic organ prolapse as measured by POP-Q and MRI. Postoperative MRIs support the inert nature of polypropylene mesh.
本研究旨在比较行 Prolift(Ethicon,Inc,Somerville,NJ)全盆底重建术患者的术前和术后盆腔器官脱垂定量(POP-Q)和磁共振成像(MRI)测量结果。
对患有 2 度或更高级别脱垂的患者进行 Prolift 手术前后的 MRI 和 POP-Q 检查。MRI 测量在最大下降时进行。确定 MRI 和 POP-Q 测量值变化之间的相关性。
纳入了 10 名受试者。在 MRI 上,膀胱膨出、肠膨出和顶点的变化具有统计学意义。POP-Q 测量的 Aa、Ba、C、Ap、Bp 和 GH 也有统计学意义的变化。POP-Q 和 MRI 变化之间显示出正相关。MRI 上可见最小的组织反应。
POP-Q 和 MRI 测量结果表明,Prolift 系统在治疗盆腔器官脱垂方面是有效的。术后 MRI 支持聚丙烯网片的惰性性质。