Suppr超能文献

使用放射色胶片进行快中子二维被动剂量学的可行性研究。

A feasibility study using radiochromic films for fast neutron 2D passive dosimetry.

机构信息

Medical Physics Graduate Program, Duke University, Durham, NC 27705, USA.

出版信息

Phys Med Biol. 2010 Sep 7;55(17):4977-92. doi: 10.1088/0031-9155/55/17/007. Epub 2010 Aug 6.

Abstract

The objective of this paper is threefold: (1) to establish sensitivity of XRQA and EBT radiochromic films to fast neutron exposure; (2) to develop a film response to radiation dose calibration curve and (3) to investigate a two-dimensional (2D) film dosimetry technique for use in establishing an experimental setup for a radiobiological irradiation of mice and to assess the dose to the mice in this setup. The films were exposed to a 10 MeV neutron beam via the (2)H(d,n)(3)He reaction. The XRQA film response was a factor of 1.39 greater than EBT film response to the 10 MeV neutron beam when exposed to a neutron dose of 165 cGy. A film response-to-soft tissue dose calibration function was established over a range of 0-10 Gy and had a goodness of fit of 0.9926 with the calibration data. The 2D film dosimetry technique estimated the neutron dose to the mice by measuring the dose using a mouse phantom and by placing a piece of film on the exterior of the experimental mouse setup. The film results were benchmarked using Monte Carlo and aluminum (Al) foil activation measurements. The radiochromic film, Monte Carlo and Al foil dose measurements were strongly correlated, and the film within the mouse phantom agreed to better than 7% of the externally mounted films. These results demonstrated the potential application of radiochromic films for passive 2D neutron dosimetry.

摘要

本文的目的有三

(1)确定 XRQA 和 EBT 光致变色胶片对快中子暴露的灵敏度;(2)开发一种胶片响应辐射剂量校准曲线;(3)研究二维(2D)胶片剂量测定技术,用于建立小鼠放射生物学辐照的实验装置,并评估该装置中老鼠的剂量。胶片通过(2)H(d,n)(3)He 反应暴露于 10 MeV 中子束。当 XRQA 胶片在 165 cGy 的中子剂量下暴露于 10 MeV 中子束时,其响应比 EBT 胶片高 1.39 倍。建立了胶片响应-软组织剂量校准函数,范围为 0-10 Gy,校准数据拟合度为 0.9926。二维胶片剂量测定技术通过使用小鼠体模测量剂量,并将胶片放置在实验小鼠装置外部,来估计小鼠的中子剂量。使用蒙特卡罗和铝(Al)箔激活测量对胶片结果进行了基准测试。光致变色胶片、蒙特卡罗和 Al 箔剂量测量结果具有很强的相关性,并且小鼠体模内的胶片与外部安装的胶片的一致性优于 7%。这些结果表明,光致变色胶片在被动二维中子剂量测定方面具有潜在的应用。

相似文献

1
A feasibility study using radiochromic films for fast neutron 2D passive dosimetry.
Phys Med Biol. 2010 Sep 7;55(17):4977-92. doi: 10.1088/0031-9155/55/17/007. Epub 2010 Aug 6.
2
The use of new GAFCHROMIC EBT film for 125I seed dosimetry in Solid Water phantom.
Med Phys. 2008 Aug;35(8):3787-99. doi: 10.1118/1.2955746.
3
Dosimetry for 131Cs and 125I seeds in solid water phantom using radiochromic EBT film.
Appl Radiat Isot. 2014 Sep;92:102-14. doi: 10.1016/j.apradiso.2014.06.014. Epub 2014 Jul 5.
6
Micrometer-resolved film dosimetry using a microscope in microbeam radiation therapy.
Med Phys. 2015 Jul;42(7):4069-79. doi: 10.1118/1.4922001.
8
A method of dosimetry for synchrotron microbeam radiation therapy using radiochromic films of different sensitivity.
Phys Med Biol. 2008 Dec 7;53(23):6861-77. doi: 10.1088/0031-9155/53/23/014. Epub 2008 Nov 12.

引用本文的文献

1
Specific issues in small animal dosimetry and irradiator calibration.
Int J Radiat Biol. 2011 Oct;87(10):1001-10. doi: 10.3109/09553002.2011.556178.

本文引用的文献

1
Precise radiochromic film dosimetry using a flat-bed document scanner.
Med Phys. 2005 Jul;32(7Part1):2245-2253. doi: 10.1118/1.1929253.
2
Optimizing the dynamic range extension of a radiochromic film dosimetry system.
Med Phys. 2009 Feb;36(2):429-37. doi: 10.1118/1.3049597.
3
Evaluation of an Epson flatbed scanner to read Gafchromic EBT films for radiation dosimetry.
Phys Med Biol. 2009 Feb 21;54(4):1073-85. doi: 10.1088/0031-9155/54/4/017. Epub 2009 Jan 23.
7
Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance.
Phys Med Biol. 2007 Jul 21;52(14):4211-25. doi: 10.1088/0031-9155/52/14/013. Epub 2007 Jun 18.
8
Absorption spectroscopy of EBT model GAFCHROMIC film.
Med Phys. 2007 Jan;34(1):112-8. doi: 10.1118/1.2400615.
9
Precautions and strategies in using a commercial flatbed scanner for radiochromic film dosimetry.
Phys Med Biol. 2007 Jan 7;52(1):231-42. doi: 10.1088/0031-9155/52/1/015. Epub 2006 Dec 18.
10
New developments in radiochromic film dosimetry.
Radiat Prot Dosimetry. 2006;120(1-4):100-6. doi: 10.1093/rpd/nci698.