Suppr超能文献

采用在线提取和电喷雾串联质谱法(HTLC-ESI-MS/MS)测定人血浆中的γ-分泌酶抑制剂 MK-0752。

Determination of the gamma-secretase inhibitor MK-0752 in human plasma by online extraction and electrospray tandem mass spectrometry (HTLC-ESI-MS/MS).

机构信息

Department of Pharmaceutical Sciences, St. Jude Children's Research Hospital, Memphis, TN 38105, USA.

出版信息

J Chromatogr B Analyt Technol Biomed Life Sci. 2010 Sep 1;878(25):2348-52. doi: 10.1016/j.jchromb.2010.07.019. Epub 2010 Jul 30.

Abstract

A sensitive and rapid HTLC-ESI-MS/MS method with an advanced online sample preparation was developed for determination of the gamma-secretase inhibitor MK-0752 in human plasma using an internal standard. Plasma samples (100 microL) were diluted and injected directly onto an online extraction column (Cohesive Cyclone MAX 0.5 mm x 50 mm, > 30 microm), the sample matrix was washed out with an aqueous solution, and retained analytes were eluted out and transferred directly to the analytical column (Phenomenex Gemini 3 micron C18 110A, 50 mm x 2.0 mm at 50 degrees C) for separation using a gradient mobile phase. The eluted analytes were then detected on an API-3000 LC-MS/MS System with ESI and a negative multiple reaction monitoring mode. The monitored ion transitions were m/z 441-->175 for MK-0752 and 496-->175 for the internal standard. Online extraction recoveries were 81%. The method was validated and was linear in the range of 0.05-50 microg/mL. Within-day and between-day precisions were<8.6%, and accuracies were 0.7 and 7.1%. This method was applied to the measurement of plasma MK-0752 levels in a Phase I study of pediatric patients with recurrent or refractory brain tumors.

摘要

建立了一种灵敏、快速的 HTLC-ESI-MS/MS 方法,该方法采用先进的在线样品制备技术,使用内标法测定人血浆中的γ-分泌酶抑制剂 MK-0752。将 100 μL 血浆样品稀释后直接注入在线萃取柱(Cohesive Cyclone MAX 0.5mm×50mm,>30μm),用水溶液洗脱样品基质,保留的分析物被洗脱出来并直接转移到分析柱(Phenomenex Gemini 3μm C18 110A,50mm×2.0mm,50°C)进行分离,采用梯度流动相。洗脱的分析物随后在 API-3000 LC-MS/MS 系统上进行检测,采用 ESI 和负多重反应监测模式。监测的离子转换为 m/z 441→175 用于 MK-0752 和 496→175 用于内标。在线萃取回收率为 81%。该方法经过验证,在 0.05-50μg/mL 范围内呈线性。日内和日间精密度均<8.6%,准确度分别为 0.7%和 7.1%。该方法应用于儿科复发性或难治性脑肿瘤患者的 I 期研究中测定血浆 MK-0752 水平。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/787b/2926936/38509c94f20b/nihms226029f1.jpg

相似文献

本文引用的文献

4
Notch signaling in pediatric malignancies.儿科恶性肿瘤中的Notch信号通路
Curr Oncol Rep. 2008 Nov;10(6):459-68. doi: 10.1007/s11912-008-0071-2.
7
Notch signaling in leukemia.白血病中的Notch信号传导
Annu Rev Pathol. 2008;3:587-613. doi: 10.1146/annurev.pathmechdis.3.121806.154300.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验