Suppr超能文献

采用柱色谱法和放射免疫分析法测定血清中的游离甲状腺素。

Determination of free thyroxine in serum using column chromatography & radioimmunoassay.

作者信息

Joseph L J, Desai K B, Velumani A, Samuel A M

机构信息

Radiation Medicine Centre, Bhabha Atomic Research Centre, Bombay.

出版信息

Indian J Med Res. 1991 Feb;94:36-40.

PMID:2071182
Abstract

A simple method for measurement of free thyroxine (FT4) levels in serum by adsorption chromatography and subsequent radioimmunoassay (RIA) is described. Assay sensitivity observed by this method was 1.2 pg/ml. Intra-assay variability was 11.2 per cent for FT4 concentrations of 7.9 pg/ml (n = 10), while interassay variability was 23.3, 9.7 and 12.9 per cent respectively for concentrations of 2.66, 12.06 and 23.96 pg/ml (n = 16). Serum FT4 concentration estimated by this method in 79 euthyroid patients was found to be 10.8 +/- 3.1 pg/ml. Values of FT4 obtained in hypothyroid and hyperthyroid patients were outside the normal range. FT4 values obtained by this method correlated well with the standard Liso-phase FT4 kit (r = 0.8) as well as free FT4 index (r = 0.93).

摘要

本文描述了一种通过吸附色谱法及后续放射免疫测定法(RIA)来测定血清中游离甲状腺素(FT4)水平的简单方法。用该方法观察到的测定灵敏度为1.2 pg/ml。对于7.9 pg/ml的FT4浓度,批内变异系数为11.2%(n = 10);而对于2.66、12.06和23.96 pg/ml的浓度,批间变异系数分别为23.3%、9.7%和12.9%(n = 16)。用该方法对79例甲状腺功能正常的患者进行血清FT4浓度测定,结果为10.8±3.1 pg/ml。甲状腺功能减退和甲状腺功能亢进患者的FT4值超出正常范围。用该方法获得的FT4值与标准Liso-phase FT4试剂盒(r = 0.8)以及游离FT4指数(r = 0.93)相关性良好。