Suppr超能文献

多曲线硬性透气性(RGP)隐形眼镜的使用对圆锥角膜地形变化的影响。

Effects of multicurve RGP contact lens use on topographic changes in keratoconus.

作者信息

Hwang Joon Seo, Lee Jin Hak, Wee Won Ryang, Kim Mee Kum

机构信息

Department of Ophthalmology, Haenam Genenral Hospital, Jeonnam, Korea.

出版信息

Korean J Ophthalmol. 2010 Aug;24(4):201-6. doi: 10.3341/kjo.2010.24.4.201. Epub 2010 Aug 3.

Abstract

PURPOSE

To evaluate the effects of wearing rigid gas permeable (RGP) contact lenses on the topographic changes in keratoconus.

METHODS

Seventy-seven keratoconic eyes that wore multicurve RGP contact lenses and 30 keratoconic eyes that wore no contact lenses were retrospectively analyzed. The mean follow-ups were 22.6 and 20.5 months in the lens-wearing and control groups, respectively. Visual acuity, comfort, daily wearing time, and corneal staining were evaluated for both groups. The changes in topographic indices were compared between the lens-wearing and control groups.

RESULTS

Multicurve RGP lens corrected logarithm of the minimum angle of resolution visual acuity of the lens-wearing group significantly improved from -0.016+/-0.065 to -0.032+/-0.10 at follow-up (p=0.05). In the lens-wearing group with advanced keratoconus, the Sim Kmax, Sim Kmin, apical power, astigmatic index, and anterior elevation significantly decreased from 57.68+/-4.26 diopter (D), 50.50+/-2.32 D, 62.79+/-5.11 D, 7.20+/-0.55 D and 67.36+/-16.30 microm to 55.51+/-4.28 D, 49.62+/-3.26 D, 60.31+/-5.41 D, 5.90+/-0.51 D and 60.61+/-16.09 microm, respectively (paired t-test, p<0.05). The irregularity index of 3 mm did not significantly change. Meanwhile, in the control group, the apical power and irregularity index increased from 55.56+/-7.25 D and 3.06+/-1.68 D to 57.11+/-7.75 D and 3.25+/-1.71 D, respectively (paired t-test, p=0.008, p=0.01).

CONCLUSIONS

Properly fitted multicurve RGP contact lenses are not likely to contribute to the progression of keratoconus.

摘要

目的

评估佩戴硬性透气性(RGP)隐形眼镜对圆锥角膜地形学变化的影响。

方法

回顾性分析77只佩戴多曲面RGP隐形眼镜的圆锥角膜眼和30只未佩戴隐形眼镜的圆锥角膜眼。佩戴镜片组和对照组的平均随访时间分别为22.6个月和20.5个月。对两组的视力、舒适度、每日佩戴时间和角膜染色情况进行评估。比较佩戴镜片组和对照组之间地形学指标的变化。

结果

随访时,佩戴多曲面RGP镜片组的最小分辨角视力对数显著改善,从-0.016±0.065提高到-0.032±0.10(p=0.05)。在圆锥角膜晚期的佩戴镜片组中,Sim Kmax、Sim Kmin、顶点屈光力、散光指数和前表面高度分别从57.68±4.26屈光度(D)、50.50±2.32 D、62.79±5.11 D、7.20±0.55 D和67.36±16.30微米显著下降至55.51±4.28 D、49.62±3.26 D、60.31±5.41 D、5.90±0.51 D和60.61±16.09微米(配对t检验,p<0.05)。3毫米处的不规则指数无显著变化。同时,在对照组中,顶点屈光力和不规则指数分别从55.56±7.25 D和3.06±1.68 D增加至57.11±7.75 D和3.25±1.71 D(配对t检验,p=0.008,p=0.01)。

结论

适配良好的多曲面RGP隐形眼镜不太可能导致圆锥角膜进展。

相似文献

1
Effects of multicurve RGP contact lens use on topographic changes in keratoconus.
Korean J Ophthalmol. 2010 Aug;24(4):201-6. doi: 10.3341/kjo.2010.24.4.201. Epub 2010 Aug 3.
2
Progression of keratoconus in patients wearing pancorneal toric edge rigid gas-permeable contact lenses.
Cont Lens Anterior Eye. 2014 Aug;37(4):251-6. doi: 10.1016/j.clae.2013.11.012. Epub 2013 Dec 17.
3
Clinical performance and fitting characteristics with a multicurve lens for keratoconus.
Eye Contact Lens. 2004 Jan;30(1):20-4. doi: 10.1097/01.ICL.0000095230.24618.03.
4
Performance and predictability of a new large diameter contact lens design in keratoconic corneae.
Cont Lens Anterior Eye. 2019 Jun;42(3):289-294. doi: 10.1016/j.clae.2019.02.014. Epub 2019 Feb 26.
7
Which soft lens power is better for piggyback in keratoconus? Part II.
Cont Lens Anterior Eye. 2015 Feb;38(1):48-53. doi: 10.1016/j.clae.2014.09.012. Epub 2014 Oct 23.
8
Rigid gas-permeable contact lens related life quality in keratoconic patients with different grades of severity.
Clin Exp Optom. 2015 Mar;98(2):150-4. doi: 10.1111/cxo.12237. Epub 2014 Dec 29.
9
Correlation between long-term use of rigid gas permeable contact lenses and endothelial morphometric changes in keratoconus patients.
Cont Lens Anterior Eye. 2022 Feb;45(1):101520. doi: 10.1016/j.clae.2021.101520. Epub 2021 Oct 20.

引用本文的文献

1
Longitudinal assessment of the progression of severe keratoconus based on corneal topography.
Sci Rep. 2024 Aug 23;14(1):19642. doi: 10.1038/s41598-024-70084-4.
2
Advances in Therapeutic Contact Lenses for the Management of Different Ocular Conditions.
J Pers Med. 2023 Nov 3;13(11):1571. doi: 10.3390/jpm13111571.
3
Comparison of Hybrid Contact Lenses and Rigid Gas-Permeable Contact Lenses in Moderate and Advanced Keratoconus.
Turk J Ophthalmol. 2023 Jun 21;53(3):142-148. doi: 10.4274/tjo.galenos.2022.82754.
4
Scleral Lens Applications Focused on Korean Patients with Various Corneal Disorders.
Korean J Ophthalmol. 2023 Apr;37(2):157-165. doi: 10.3341/kjo.2022.0164. Epub 2023 Mar 23.
5
Update on Contact Lens Treatment of Keratoconus.
Turk J Ophthalmol. 2020 Aug 26;50(4):234-244. doi: 10.4274/tjo.galenos.2020.70481.
6
Results in keratoconus correction with Kerasoft 3 Contact lenses.
Rom J Ophthalmol. 2020 Apr-Jun;64(2):122-127.
7
Nonsurgical Procedures for Keratoconus Management.
J Ophthalmol. 2017;2017:9707650. doi: 10.1155/2017/9707650. Epub 2017 Dec 21.
9
Tear metabolite changes in keratoconus.
Exp Eye Res. 2015 Mar;132:1-8. doi: 10.1016/j.exer.2015.01.007. Epub 2015 Jan 9.
10

本文引用的文献

1
Evaluation of keratoconus in Asians: role of Orbscan II and Tomey TMS-2 corneal topography.
Am J Ophthalmol. 2007 Mar;143(3):390-400. doi: 10.1016/j.ajo.2006.11.030. Epub 2006 Dec 21.
3
A new method for grading the severity of keratoconus: the Keratoconus Severity Score (KSS).
Cornea. 2006 Aug;25(7):794-800. doi: 10.1097/01.ico.0000226359.26678.d1.
4
Automated keratoconus detection using height data of anterior and posterior corneal surfaces.
Jpn J Ophthalmol. 2006 Sep-Oct;50(5):409-416. doi: 10.1007/s10384-006-0349-6.
5
Corneal elevation indices in normal and keratoconic eyes.
J Cataract Refract Surg. 2006 Aug;32(8):1281-7. doi: 10.1016/j.jcrs.2006.02.060.
6
Longitudinal changes in corneal curvature in keratoconus.
Cornea. 2006 Apr;25(3):296-305. doi: 10.1097/01.ico.0000178728.57435.df.
8
Orbscan computerized topography: attributes, applications, and limitations.
J Cataract Refract Surg. 2005 Jan;31(1):205-20. doi: 10.1016/j.jcrs.2004.09.047.
9
Keratoconus fittings: apical clearance or apical support?
Eye Contact Lens. 2004 Jul;30(3):147-55. doi: 10.1097/01.icl.0000138717.57592.36.
10
Corneal pachymetry in normal and keratoconic eyes: Orbscan II versus ultrasound.
J Cataract Refract Surg. 2004 Jun;30(6):1272-7. doi: 10.1016/j.jcrs.2003.11.049.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验