Corneal pachymetry in normal and keratoconic eyes: Orbscan II versus ultrasound.

作者信息

Gherghel D, Hosking S L, Mantry S, Banerjee S, Naroo S A, Shah S

机构信息

Department of Ophthalmology, Heartlands and Solihull NHS Trust, Birmingham, United Kingdom.

出版信息

J Cataract Refract Surg. 2004 Jun;30(6):1272-7. doi: 10.1016/j.jcrs.2003.11.049.

Abstract

PURPOSE

To compare corneal thickness measurements using Orbscan II (OII) and ultrasonic (US) pachymetry in normal and in keratoconic eyes.

SETTING

Eye Department, Heartlands and Solihull NHS Trust, Birmingham, United Kingdom.

METHODS

Central corneal thickness (CCT) was measured by means of OII and US pachymetry in 1 eye of 72 normal subjects and 36 keratoconus patients. The apical corneal thickness (ACT) in keratoconus patients was also evaluated using each method. The mean of the difference, standard deviation (SD), and 95% limits of agreement (LoA = mean +/- 2 SD), with and without applying the default linear correction factor (LCF), were determined for each sample. The Student t test was used to identify significant differences between methods, and the correlation between methods was determined using the Pearson bivariate correlation. Bland-Altman analysis was performed to confirm that the results of the 2 instruments were clinically comparable.

RESULTS

In normal eyes, the mean difference (+/- 95% LoA) in CCT was 1.04 microm +/- 68.52 (SD) (P>.05; r = 0.71) when the LCF was used and 46.73 +/- 75.40 microm (P =.0001; r = 0.71) without the LCF. In keratoconus patients, the mean difference (+/- 95% LoA) in CCT between methods was 42.46 +/- 66.56 microm (P<.0001: r = 0.85) with the LCF, and 2.51 +/- 73.00 microm (P>.05: r = 0.85) without the LCF. The mean difference (+/- 95% LoA) in ACT for this group was 49.24 +/- 60.88 microm (P<.0001: r = 0.89) with the LCF and 12.71 +/- 68.14 microm (P =.0077; r = 0.89) when the LCF was not used.

CONCLUSIONS

This study suggests that OII and US pachymetry provide similar readings for CCT in normal subjects when an LCF is used. In keratoconus patients, OII provides a valid clinical tool for the noninvasive assessment of CCT when the LCF is not applied.

摘要

目的

比较Orbscan II(OII)和超声(US)测厚法测量正常眼和圆锥角膜眼的角膜厚度。

设置

英国伯明翰市Heartlands和索利哈尔国民保健服务信托基金眼科。

方法

采用OII和超声测厚法测量72名正常受试者和36名圆锥角膜患者单眼的中央角膜厚度(CCT)。还使用每种方法评估圆锥角膜患者的角膜顶点厚度(ACT)。确定每个样本在应用和未应用默认线性校正因子(LCF)时的平均差值、标准差(SD)和95%一致性界限(LoA = 平均值±2 SD)。采用Student t检验确定方法之间的显著差异,并使用Pearson双变量相关性确定方法之间的相关性。进行Bland-Altman分析以确认两种仪器的结果在临床上具有可比性。

结果

在正常眼中,使用LCF时CCT的平均差值(±95% LoA)为1.04微米±68.52(SD)(P>0.05;r = 0.71),未使用LCF时为46.73±75.40微米(P = 0.0001;r = 0.71)。在圆锥角膜患者中,使用LCF时两种方法之间CCT的平均差值(±95% LoA)为42.46±66.56微米(P<0.0001:r = 0.85),未使用LCF时为2.51±73.00微米(P>0.05:r = 0.85)。该组ACT的平均差值(±95% LoA)使用LCF时为49.24±60.88微米(P<0.0001:r = 0.89),未使用LCF时为12.71±68.14微米(P = 0.0077;r = 0.89)。

结论

本研究表明,使用LCF时,OII和超声测厚法在正常受试者中测量CCT的读数相似。在圆锥角膜患者中,不应用LCF时,OII为CCT的无创评估提供了一种有效的临床工具。