Welsh B M
Appl Opt. 1991 Dec 1;30(34):5021-30. doi: 10.1364/AO.30.005021.
The use of laser guide stars in conjunction with adaptive optical telescopes offers the possibility of nearly diffraction-limited imaging performance from large, ground-based telescopes. We investigate the expected imaging performance of an adaptive telescope, using laser guide stars created in the mesospheric sodium (Na) layer. A 2-3-m class telescope is analyzed for the case of a single, on-axis guide star at an altitude of 92 km (the nominal height of the mesospheric Na layer). We analyze an annular telescope pupil with approximately 15 wave-front sensor subapertures and mirror actuators spanning the pupil diameter. The imaging performance is quantified in terms of the pupil-averaged rms wave-front error, the optical transfer function, the point spread function, the Strehl ratio, and finally the angular resolution. The performance analysis takes into account the degradation caused by the limitation of the wave-front sensor as well as the deformable mirror. These limitations include the finite spacing and size of the wave-front sensor subapertures and the spacing and influence function of the mirror actuators. The effects of anisoplanatism and shot noise are also included in the analysis. The results of the investigation indicate that a 3-m adaptive telescope using a single Na guide star is capable of achieving a Strehl ratio of 0.57 and an angular resolution nearly matching that of diffraction-limited performance (0.05 arcsec). This performance is achieved assuming that r(0) = 20 cm and a 5-W laser is used to create the guide star. The effect of variations in seeing conditions and guide star brightness is also investigated.
将激光导星与自适应光学望远镜结合使用,有望使大型地基望远镜实现接近衍射极限的成像性能。我们研究了使用中层钠(Na)层中产生的激光导星的自适应望远镜的预期成像性能。针对在92公里高度(中层钠层的标称高度)有一颗轴上导星的情况,分析了一台2 - 3米口径的望远镜。我们分析了一个环形望远镜光瞳,其具有大约15个波前传感器子孔径以及跨越光瞳直径的镜面驱动器。成像性能通过光瞳平均均方根波前误差、光学传递函数、点扩散函数、斯特列尔比以及最终的角分辨率来量化。性能分析考虑了波前传感器以及可变形镜的限制所导致的性能下降。这些限制包括波前传感器子孔径的有限间距和尺寸以及镜面驱动器的间距和影响函数。分析中还包括了非等晕性和散粒噪声的影响。研究结果表明,使用单个钠导星的3米自适应望远镜能够实现0.57的斯特列尔比以及几乎与衍射极限性能(0.05角秒)相匹配的角分辨率。假设r(0) = 20厘米且使用5瓦激光器来产生导星时可实现此性能。还研究了视宁度条件和导星亮度变化的影响。