Suppr超能文献

Determining the accuracy of articulator interchangeability.

作者信息

Kitzis G D, Millstein P L, Nathanson D

机构信息

Department of Periodontology, State University of New York, School of Dental Medicine, Stony Brook.

出版信息

J Prosthet Dent. 1991 Jun;65(6):845-8. doi: 10.1016/s0022-3913(05)80025-3.

Abstract

Twelve articulators (Denar D5-A and Mark II) were calibrated using the Denar Field Inspection Gage device. Silicone interocclusal records and the split cast method were used to test the positional accuracy of mounted casts transferred from one articulator to another. The interchangeability was performed by three independent observers. The results indicate that calibrated articulators can be used to transfer casts between articulators without a loss of positional accuracy.