Stress distribution in retentive arms of combination clasps used on premolars.

作者信息

Sandu Liliana, Topala Florin, Porojan Sorin

机构信息

Specialization Dental Technology, University School of Dentistry, University of Medicine and Pharmacy, Timisoara, Romania.

出版信息

J Appl Biomater Biomech. 2010 May-Aug;8(2):76-81.

PMID:20740469
Abstract

INTRODUCTION

Stresses resulting from cast clasp arms during insertion and the removal of removable partial dentures are the main causes of deformations or fractures. Therefore, achieving clasp designs producing less stress is very important.

OBJECTIVE

Retentive clasp arms used for premolars were investigated through the reverse engineering approach. The aim was to determine stress distribution in oval and half-oval clasps cross-sections in order to analyse biomechanical behavior.

MATERIAL AND METHODS

Purposely designed experimental three-dimensional (3D) models of the clasp arms were constructed on the buccal surface of an upper first premolar, to be used for structural simulations. 3D teeth models obtained after laser scanning were used as a support for retentive clasp arms modeling. Parameters of the clasp arms like length, thickness and cross-section were considered for the simulation of stainless steel wires. A concentrated load of 5 N was applied at the inner tip of the clasp arm.

RESULTS

A precise model of the coronal buccal surface of an upper first premolar was generated. This model was a useful tool in designing stainless steel clasp arms of different thickness and cross-section. In all cases, high stress values were located on the inner surface of the clasp arm, in the part located above the height of the contour. A similar bending stiffness was observed between the half-round cross-section design with a diameter of 1 mm and the round cross-section design with a diameter between 0.6 and 0.7 mm.

CONCLUSIONS

This in vitro study demonstrated that the reverse engineering approach and structural analyses provide a powerful tool for designing clasps and visualizing fracture risk areas and for choosing the adequate cross-section for each case. Within the limitations of this study, it was suggested that, on premolars, the biomechanical performance of half-round cross-sections for the retentive arms may be higher than round sections of clasp arms showing similar mechanical stiffness.

摘要

相似文献

1
Stress distribution in retentive arms of combination clasps used on premolars.
J Appl Biomater Biomech. 2010 May-Aug;8(2):76-81.
2
A new design for partial denture circumferential clasp arms.局部义齿环形卡环臂的一种新设计。
Aust Dent J. 1996 Oct;41(5):317-23. doi: 10.1111/j.1834-7819.1996.tb03140.x.
3
Finite element stress analysis and fatigue behavior of cast circumferential clasps.铸造环形卡环的有限元应力分析及疲劳行为
J Prosthet Dent. 2007 Jan;97(1):39-44. doi: 10.1016/j.prosdent.2006.11.003.
4
[A three-dimensional finite element analysis on relationship between abutment undercut and retentive arm width of cast cobalt-chromium three-arm clasp].[铸造钴铬三臂卡环基牙倒凹与固位臂宽度关系的三维有限元分析]
Zhonghua Kou Qiang Yi Xue Za Zhi. 2007 May;42(5):276-9.
5
[Finite element analyses of retention of removable partial denture circumferential clasps manufactured by selective laser melting].[选择性激光熔化制造的可摘局部义齿环形卡环固位的有限元分析]
Beijing Da Xue Xue Bao Yi Xue Ban. 2022 Feb 18;54(1):105-112. doi: 10.19723/j.issn.1671-167X.2022.01.017.
6
Comparison of cast Ti-Ni alloy clasp retention with conventional removable partial denture clasps.铸造钛镍合金卡环固位与传统可摘局部义齿卡环的比较。
J Prosthet Dent. 2004 Apr;91(4):374-82. doi: 10.1016/j.prosdent.2004.02.015.
7
Dynamic retentive force of a mandibular unilateral removable partial denture framework with a back-action clasp.具有回力卡环的下颌单侧可摘局部义齿支架的动态固位力
J Med Dent Sci. 2001 Dec;48(4):105-11.
8
An analytical model to design circumferential clasps for laser-sintered removable partial dentures.用于设计激光烧结可摘局部义齿周向卡环的分析模型。
Dent Mater. 2018 Oct;34(10):1474-1482. doi: 10.1016/j.dental.2018.06.011. Epub 2018 Jun 21.
9
Comparison of the retentive characteristics of cobalt-chromium and commercially pure titanium clasps using a novel method.使用一种新方法对钴铬合金和商业纯钛卡环的固位特性进行比较。
Int J Prosthodont. 2006 Jul-Aug;19(4):371-2.
10
Fitness and retentive force of cobalt-chromium alloy clasps fabricated with repeated laser sintering and milling.经反复激光烧结和铣削加工制作的钴铬合金卡环的适配性和固位力。
J Prosthodont Res. 2018 Jul;62(3):342-346. doi: 10.1016/j.jpor.2018.01.001. Epub 2018 Feb 7.

引用本文的文献

1
Biomechanics in Removable Partial Dentures: A Literature Review of FEA-Based Studies.可摘局部义齿中的生物力学:基于有限元分析的研究文献综述。
Biomed Res Int. 2021 Aug 26;2021:5699962. doi: 10.1155/2021/5699962. eCollection 2021.