[Cardiopulmonary bypass over 24 hours without systemic anticoagulation: new horizons?].

作者信息

von Segesser L K, Turina M

机构信息

Klinik für Herzgefässchirurgie, Universitätsspital Zürich.

出版信息

Helv Chir Acta. 1990 Oct;57(2):389-93.

PMID:2074206
Abstract

Open chest cardiopulmonary bypass was evaluated in eight canine experiments (mean bodyweight 37 +/- 7 kg) over 24 hours using either heparin surface coated equipment without systemic anticoagulation or standard equipment with systemic heparinization (ACT greater than 400 s). Mean duration of perfusion achieved was 23 +/- 2 hours in the group perfused without systemic anticoagulation versus 21 +/- 6 hours in the group with: [table; see text] These results show, that prolonged open chest perfusion by the means of heparin surface coated equipment without systemic anticoagulation can be performed with reduced blood trauma and without transfusion of blood products for 12 hours.

摘要

相似文献

1
[Cardiopulmonary bypass over 24 hours without systemic anticoagulation: new horizons?].
Helv Chir Acta. 1990 Oct;57(2):389-93.
2
Cardiopulmonary bypass without systemic heparinization. Performance of heparin-coated oxygenators in comparison with classic membrane and bubble oxygenators.无全身肝素化的体外循环。肝素涂层氧合器与传统膜式和鼓泡式氧合器的性能比较。
J Thorac Cardiovasc Surg. 1989 Sep;98(3):386-96.
3
Deleterious effects of cardiopulmonary bypass on early graft function after single lung allotransplantation: evaluation of a heparin-coated bypass circuit.体外循环对单肺移植术后早期移植肺功能的有害影响:肝素涂层体外循环回路的评估
J Heart Lung Transplant. 1994 May-Jun;13(3):498-507.
4
Reduction and elimination of systemic heparinization during cardiopulmonary bypass.
J Thorac Cardiovasc Surg. 1992 Apr;103(4):790-8; discussion 798-9.
5
Comparison of two heparin-coated extracorporeal circuits with reduced systemic anticoagulation in routine coronary artery bypass operations.常规冠状动脉搭桥手术中两种采用减少全身抗凝的肝素涂层体外循环回路的比较。
J Thorac Cardiovasc Surg. 2001 Feb;121(2):324-30. doi: 10.1067/mtc.2001.111205.
6
Long term cardiopulmonary bypass without systemic heparinization.
Int J Artif Organs. 1990 Oct;13(10):687-91.
7
Clinical and biomaterial evaluation of hyaluronan-based heparin-bonded extracorporeal circuits with reduced versus full systemic anticoagulation in reoperation for coronary revascularization.在冠状动脉血运重建再次手术中,对基于透明质酸的肝素结合体外循环进行临床和生物材料评估,比较减少全身抗凝与完全全身抗凝的效果。
J Cardiovasc Med (Hagerstown). 2009 Feb;10(2):135-42. doi: 10.2459/JCM.0b013e32831eef9d.
8
Heparin-bonded surfaces in extracorporeal membrane oxygenation for cardiac support.
Ann Thorac Surg. 1996 Jan;61(1):330-5; discussion 340-1. doi: 10.1016/0003-4975(95)01011-4.
9
A comparison of activated coagulation time-based techniques for anticoagulation during cardiac surgery with cardiopulmonary bypass.基于活化凝血时间的技术在体外循环心脏手术中抗凝作用的比较。
J Cardiothorac Vasc Anesth. 2008 Feb;22(1):47-52. doi: 10.1053/j.jvca.2007.07.011. Epub 2007 Nov 7.
10
Evaluation of heparin-coated circuits with full heparin dose strategy.
Ann Thorac Cardiovasc Surg. 1999 Jun;5(3):156-63.