Suppr超能文献

五种下颌大连接体在局部可摘义齿修复中的刚性比较——通过负载挠度。

A comparison of the rigidity of five mandibular major connectors for partial removable dental prostheses via load deflection.

机构信息

Department of Restorative Dentistry, School of Dentistry, Loma Linda University, Loma Linda, CA 92350, USA.

出版信息

J Prosthet Dent. 2010 Sep;104(3):182-90. doi: 10.1016/S0022-3913(10)60118-7.

Abstract

STATEMENT OF PROBLEM

The rigidity of the major connector for partial removable dental prostheses (PRDP) has not been well defined. There is little scientific evidence to support specific standards relative to the dimensions of a casting and their effect on long-term function of the PRDP or the supporting tissues.

PURPOSE

The purpose of this study was to compare in vitro the effects of load deflection of 5 clinically used mandibular major connector forms.

MATERIAL AND METHODS

A partially edentulous dental cast of a patient with the mandibular anterior teeth remaining was used as the test model. Lingual plate (LP), continuous bar (CB), sublingual bar (SB), lingual bar (LB), and dental lingual bar (DLB) specimens (n=5) were waxed on identical refractory casts, then cast in cobalt base alloy and finished. Each specimen was placed on a custom test table and statically loaded in the contralateral second molar region with 500 g in the horizontal and vertical planes. Deflections were measured at the terminal abutment rest seat, anterior to the load. Comparisons between group means were evaluated using the Dunnett T3 method, assuming unequal variances, for all pairwise tests at a .05 significance level and for 95% confidence intervals for group mean differences. Differences within the groups for vertical versus horizontal deflections were compared using a paired t test and Bonferroni correction (alpha=.05 for all tests).

RESULTS

Horizontal deflection between LP and LB, CB and LB, and SB and LB were significant, with the first in each comparison having the least amount of deflection. A significant difference was also seen in the vertical deflection, with the first in each comparison observed to have deflected the least for LP versus CB, LP versus LB, LP versus DLB, CB versus DLB, LB versus DLB, and SB versus DLB. The amount of vertical deflection was significantly greater than the horizontal deflection for all 5 mandibular major connectors (P< or =.033).

CONCLUSIONS

In the horizontal plane, a significant difference in the amount of deflection was seen between the LP and LB, CB and LB, and LB and SB. In the vertical plane, the LP deflected significantly less than the CB, LB, and DLB. In addition, the DLB deflected significantly more in the vertical plane when compared to the CB, LB, and SB. All 5 mandibular major connectors had a significantly greater amount of vertical deflection as compared to horizontal deflection.

摘要

问题陈述

部分可摘义齿的主要连接件的刚性尚未得到很好的定义。几乎没有科学证据支持与铸件尺寸及其对义齿长期功能和支持组织的影响有关的具体标准。

目的

本研究的目的是比较 5 种临床使用的下颌主要连接件形式的体外载荷挠度。

材料与方法

采用一位下颌前牙缺失患者的部分义齿牙列模型作为试验模型。将舌侧板(LP)、连续杆(CB)、舌侧下杆(SB)、舌侧杆(LB)和牙科舌侧杆(DLB)试件(n=5)蜡型于相同的耐火铸件上,然后用钴基合金铸造和加工完成。将每个试件放置在定制的测试台上,在水平和垂直方向上于对侧第二磨牙区域以 500g 的力静态加载。在加载的前牙支托休息座处测量末端支台的挠度。采用 Dunnett T3 法对组间均值进行比较,对于所有两两比较,假设方差不等,检验水平为.05,组间均值差异置信区间为 95%。采用配对 t 检验和 Bonferroni 校正(所有检验的α值均为.05)比较组内垂直与水平挠度的差异。

结果

LP 与 LB、CB 与 LB 和 SB 与 LB 之间的水平挠度存在显著差异,每组中的第一个有最小的挠度。垂直挠度也有显著差异,LP 与 CB、LP 与 LB、LP 与 DLB、CB 与 DLB、LB 与 DLB 和 SB 与 DLB 之间观察到的第一个挠度最小。5 种下颌主要连接件的垂直挠度均明显大于水平挠度(P<或=.033)。

结论

在水平方向,LP 和 LB、CB 和 LB 以及 LB 和 SB 之间的挠度差异有统计学意义。在垂直方向,LP 的挠度明显小于 CB、LB 和 DLB。此外,与 CB、LB 和 SB 相比,DLB 在垂直方向的挠度明显更大。与水平挠度相比,所有 5 种下颌主要连接件的垂直挠度均显著更大。