Olson A K, MacPherson M G, Hartwell G R, Weller R N, Kulild J C
U.S. Army Dental Activity, Fort Campbell, KY.
J Endod. 1990 Aug;16(8):361-4. doi: 10.1016/s0099-2399(06)81906-0.
An in vitro dye leakage study was performed to evaluate the sealing ability of the following retrofilling materials: high- and low-temperature injectable thermoplasticized gutta-percha with and without sealer, a glass ionomer cement, and amalgam with and without varnish. The roots of 105 extracted human maxillary anterior teeth were instrumented and obturated with single cones of gutta-percha and sealer. The apical 3 mm of the roots were then resected and 2-mm deep retrograde preparations were prepared. Each root was then randomly placed into one of seven groups and retrofilled with one of the test materials. After 72 h in India ink, the roots were cleared and evaluated for leakage using a stereomicroscope. Statistical analysis of the results indicated that injectable high-temperature gutta-percha without sealer demonstrated significantly more leakage than the other materials. There were no significant differences in leakage among the other evaluated materials.