• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

吻合器行狄克逊吻合术的经验。

Experience with stapling Dixon's anastomosis.

作者信息

Köves I, Besznyák I, Molnár L

机构信息

Department of Surgery, National Cancer Institute, Budapest, Hungary.

出版信息

Acta Chir Hung. 1990;31(2):125-31.

PMID:2082633
Abstract

The techniques of Dixon anastomosis by end-to-side EEA stapler is reviewed, applied successfully in 48 cases. Results are compared with those of 125 Dixon's operations previously performed by the authors manually. In their opinion, the process reviewed is rapid, reliable and safe and so it can be recommended for use.

摘要

回顾了使用端端吻合器进行狄克逊吻合术的技术,该技术已成功应用于48例患者。将结果与作者之前手动进行的125例狄克逊手术的结果进行了比较。他们认为,所回顾的手术过程快速、可靠且安全,因此可以推荐使用。

相似文献

1
Experience with stapling Dixon's anastomosis.吻合器行狄克逊吻合术的经验。
Acta Chir Hung. 1990;31(2):125-31.
2
[Use of the EEA stapler in surgery of the rectum and rectosigmoid junction].[EEA吻合器在直肠及直肠乙状结肠交界处手术中的应用]
Lijec Vjesn. 1989 Jun-Jul;111(6-7):215-7.
3
Dixon's anastomosis with "double-stapling" technique: experience with 235 cases.采用“双吻合器”技术的狄克逊吻合术:235例经验
Acta Chir Hung. 1994;34(1-2):139-49.
4
[Rectosigmoidectomy and end to end coloanal anastomosis with mechanical stapler for treatement of Hirschsprung disease].
Cir Pediatr. 2004 Apr;17(2):61-4.
5
The triple stapling procedure as an improved technique for low anterior anastomosis using the EEA stapler.三重吻合技术作为一种使用端端吻合器进行低位前吻合术的改良技术。
Surg Gynecol Obstet. 1988 Jun;166(6):553-4.
6
[Resection of the sigmoid via laparoscopy: an experimental study of its feasibility].
G Chir. 1992 Oct;13(10):501-7.
7
[Conservative coloproctectomy: the advantages of a circular trans-suture staple anastomosis after linear stapling of the everted rectum. Preliminary results].
Chirurgie. 1989;115(6):387-92.
8
The use of the Roticulator TA device as a protractor and technical aid in performing double-stapled anastomosis of the colon and rectum.
Surg Gynecol Obstet. 1989 Jun;168(6):549.
9
Surgical treatment of Chagasic megacolon by abdominal rectosigmoidectomy with immediate posterior end-to-side stapling (Habr-Gama technique).采用腹直乙状结肠切除术并立即进行后壁端侧吻合术(哈布尔-加马技术)治疗恰加斯病性巨结肠。
Dis Colon Rectum. 2006 Sep;49(9):1371-8. doi: 10.1007/s10350-006-0639-6.
10
Transcolonic approach for a stapled end-to-end colorectal anastomosis in low anterior resection.低位前切除术中经结肠途径行吻合器端端结直肠吻合术
Hepatogastroenterology. 1996 Jul-Aug;43(10):832-4.