PURPOSE

To evaluate the accuracy of ultrasonography (US) in determining the anatomic variations in the first extensor compartment of the wrist.

MATERIALS AND METHODS

Approval from the anatomic donations department was obtained. The first extensor compartment of the wrist of 40 nonembalmed cadaveric forearms (15 male and 25 female; age range at death, 65-100 years) were assessed at US by two observers for the presence or absence of a vertical septum, the presence or absence of an osseous ridge with a double groove in the bony floor, and whether there were single or multiple slips of the abductor pollicis longus and the extensor pollicis brevis tendons. These findings were also evaluated at dissection.

RESULTS

The accuracies of US in depicting a septum and an osseous ridge with a double groove were respectively 95% (95% confidence interval [CI]: 83%, 99%) and 100% (95% CI: 91%, 100%). At dissection, a septum was invariably associated with the presence of an osseous ridge. The accuracies of US in depicting multiple tendon slips of the abductor pollicis longus and the extensor pollicis brevis were respectively 80% (95% CI: 64%, 91%) and 97% (95% CI: 86%, 100%).

CONCLUSION

US was highly accurate in depicting anatomic variations in the first extensor compartment. US detection of an osseous ridge was an indirect sign of the presence of a septum dividing the first extensor compartment into two subcompartments.

摘要

目的

评估超声(US)在确定腕部第一伸肌间隔解剖变异中的准确性。

材料与方法

获得解剖捐赠部门的批准。对 40 例未防腐的尸体前臂(15 例男性,25 例女性;死亡时的年龄范围为 65-100 岁)的腕部第一伸肌间隔进行 US 检查,由两名观察者评估是否存在垂直隔膜、骨地板上是否存在具有双槽的骨性嵴,以及拇长展肌和拇短伸肌肌腱是否存在单一或多个滑液鞘。这些发现也在解剖时进行了评估。

结果

US 显示隔膜和具有双槽的骨性嵴的准确性分别为 95%(95%置信区间[CI]:83%,99%)和 100%(95%CI:91%,100%)。在解剖时,隔膜总是与骨性嵴的存在相关。US 显示拇长展肌和拇短伸肌肌腱多个滑液鞘的准确性分别为 80%(95%CI:64%,91%)和 97%(95%CI:86%,100%)。

结论

US 高度准确地描绘了第一伸肌间隔的解剖变异。US 检测骨性嵴是将第一伸肌间隔分为两个亚间隔的隔膜存在的间接征象。