Department for Trauma Surgery, Center for Musculosceletal Surgery, Johannes Gutenberg-University, Mainz, Germany.
J Shoulder Elbow Surg. 2010 Oct;19(7):965-72. doi: 10.1016/j.jse.2010.05.022.
Radial head arthroplasty is considered the treatment of choice for unreconstructable radial head fractures in the acute fracture situation. Although short-term results in the current literature are promising, replacement of the radial head remains controversial as long-term results are still missing. We report our 8.8-year results after treatment with a bipolar radial head prosthesis by Judet.
In our department, 19 patients were treated with bipolar radial head arthroplasty between 1997 and 2001. Seventeen of these patients-14 men and 3 women-were examined retrospectively after 106 months (range, 78-139). Of these, 9 patients were treated primarily, 7 patients secondarily, and 1 because of a tumor.
On the Mayo Elbow Performance Score, 6 patients achieved excellent results, 10 good, and one fair. The mean DASH score was 9.8 (range, 0-34). No differences were seen between primary and secondary implantation. Flexion averaged 124° (range, 110-150°), the extension deficit was 21° (range, 0-40°), pronation 64° (range, 30-90°), and supination 64° (range, 30-90°). The following complications were seen: 2 dislocations and 8 cases of degenerative changes of the capitellum, 1 with severe erosion. Signs of ulnohumeral arthrosis were found in 12 patients. No evidence of loosening, radiolucencies, or proximal bone resorption was detected.
Despite major primary complications and high incidence of radiographic signs of degenerative changes after 8.8 years, mainly good clinical results were achieved with Judet's bipolar prosthesis.
桡骨头置换术被认为是急性骨折情况下不可重建的桡骨头骨折的治疗选择。尽管目前文献中的短期结果很有希望,但桡骨头置换术仍然存在争议,因为长期结果仍然缺失。我们报告了使用 Judet 双极桡骨头假体治疗的 8.8 年结果。
在我们的部门,19 名患者在 1997 年至 2001 年间接受了双极桡骨头置换术治疗。其中 17 名患者-14 名男性和 3 名女性-在 106 个月后(范围,78-139)进行了回顾性检查。其中,9 名患者是初次治疗,7 名患者是二次治疗,1 名患者是因为肿瘤。
在 Mayo 肘部功能评分上,6 名患者获得了优秀的结果,10 名患者获得了良好的结果,1 名患者获得了一般的结果。平均 DASH 评分为 9.8(范围,0-34)。初次和二次植入之间没有差异。平均屈曲度为 124°(范围,110-150°),伸展不足为 21°(范围,0-40°),旋前 64°(范围,30-90°),旋后 64°(范围,30-90°)。出现了以下并发症:2 例脱位和 8 例肱骨小头退行性改变,1 例严重侵蚀。12 名患者发现尺桡关节炎的迹象。未发现松动、放射性透亮线或近端骨吸收的证据。
尽管存在主要的初次并发症和 8.8 年后退行性改变的放射学征象发生率较高,但使用 Judet 的双极假体仍获得了主要的良好临床结果。