BACKGROUND

The Intracardiac Echocardiography Guided Cardioversion Helps Interventional Procedures study evaluated the concordance of intracardiac echocardiography (ICE) with transesophageal echocardiography (TEE) in patients with atrial fibrillation (AF).

METHODS AND RESULTS

Patients with AF undergoing right heart catheterization underwent left atrium (LA) and interatrial septal (IAS) imaging by TEE and ICE. A blinded comparison of the 2 modalities was performed at a core laboratory. Ninety-five patients aged 58 ± 12 years completed the study. The LA was profiled in all patients with both techniques, and concordance for image quality was 96%. LA appendage (LAA) imaging was achieved in 85% with ICE and 96% with TEE. There was no difference in the presence of spontaneous echo contrast between ICE and TEE during LA imaging, but there was a trend toward a greater incidence in the LAA with TEE (P = 0.109). Intracardiac thrombus was uncommonly seen (TEE, 6.9%; ICE, 5.2%). The concordance for the presence or absence of thrombus was 97% in the LA and 92% in the LAA, but the latter was detected more frequently with TEE. IAS imaging was achieved in 91% with ICE and in 97% with TEE (P = 0.177). Concordance for patent foramen ovale and atrial septal aneurysms was 100% and 96%, respectively. A negative ICE examination was associated with absence of dense echo contrast or thrombus on TEE in 86%.

CONCLUSIONS

This study provides validation for the use of ICE for LA and IAS imaging. ICE imaging was less sensitive compared to TEE for LAA thrombus identification. Clinical Trial Registration- URL: http://www.clinicaltrials.gov. Unique identifier: NCT00281073.

摘要

背景

心内超声心动图引导的电复律有助于介入程序研究评估了心内超声心动图(ICE)与经食管超声心动图(TEE)在心房颤动(AF)患者中的一致性。

方法和结果

接受右心导管检查的 AF 患者接受 TEE 和 ICE 进行左心房(LA)和房间隔(IAS)成像。在核心实验室进行了两种模式的盲法比较。95 名年龄 58±12 岁的患者完成了研究。两种技术均对 LA 进行了成像,图像质量的一致性为 96%。ICE 可获得 85%的 LA 附件(LAA)成像,TEE 可获得 96%的成像。在 LA 成像期间,ICE 和 TEE 之间的自发性回声对比的存在没有差异,但 TEE 中 LAA 的发生率有增加的趋势(P=0.109)。心内血栓少见(TEE,6.9%;ICE,5.2%)。LA 和 LAA 中血栓存在或不存在的一致性分别为 97%和 92%,但 TEE 检测到的血栓更多。ICE 可获得 91%的 IAS 成像,TEE 可获得 97%的成像(P=0.177)。卵圆孔未闭和房间隔动脉瘤的一致性分别为 100%和 96%。ICE 检查阴性与 TEE 上无致密回声对比或血栓相关的比例为 86%。

结论

这项研究为 LA 和 IAS 成像的 ICE 使用提供了验证。与 TEE 相比,ICE 成像对 LAA 血栓的识别敏感性较低。临床试验注册-网址:http://www.clinicaltrials.gov。唯一标识符:NCT00281073。