使用复曲面和球面软性角膜接触镜矫正散光的成功率。

Success rates in the correction of astigmatism with toric and spherical soft contact lens fittings.

作者信息

Kurna Sevda Aydin, Sengör Tomris, Un Murat, Aki Suat

机构信息

Fatih Sultan Mehmet Education and Research Hospital, Ophthalmology Clinics, Istanbul, Turkey.

出版信息

Clin Ophthalmol. 2010 Sep 7;4:959-66. doi: 10.2147/opth.s9464.

Abstract

OBJECTIVES

To evaluate success rates in the correction of astigmatism with toric and spherical soft contact lens fitting.

METHODS

30 patients with soft toric lenses having more than 1.25 D of corneal astigmatism (25 eyes; Group A) or having 0.75-1.25 D of corneal astigmatism (22 eyes; Group B) and 30 patients with soft spheric lenses having 0.75-1.25 D of corneal astigmatism (28 eyes; Group C) or less than 0.75 D of corneal astigmatism (23 eyes; Group D) were included in the study. Corrected and uncorrected monocular visual acuity measurement with logMAR, biomicroscopic properties, autorefractometry and corneal topography were performed for all patients immediately before and at least 20 minutes after the application of contact lenses. Success of contact lens fitting was evaluated by three parameters: astigmatic neutralization, visual success, and retinal deviation.

RESULTS

After soft toric lens application, spheric dioptres, cylindric and keratometric astigmatism, and retinal deviation decreased significantly in Groups A and B (P < 0.05). In Group C, spheric dioptres and retinal deviation decreased (P < 0.05), while cylindric and keratometric astigmatism did not change significantly (P > 0.05). In Group D, spheric dioptres, retinal deviation, and cylindric astigmatism decreased (P < 0.05). Keratometric astigmatism did not change significantly (P > 0.05) and astigmatic neutralization even increased.

CONCLUSIONS

Visual acuity and residual spherical equivalent refraction remained between tolerable limits with the use of toric and spheric contact lenses. Spherical lenses failed to mask corneal toricity during topography, while toric lenses caused central neutralization and decrease in corneal cylinder in low and moderate astigmatic eyes.

摘要

目的

评估使用复曲面和球面软性接触镜矫正散光的成功率。

方法

纳入30例软性复曲面接触镜患者,其中角膜散光超过1.25 D的患者25眼(A组)或角膜散光为0.75 - 1.25 D的患者22眼(B组),以及30例软性球面接触镜患者,其中角膜散光为0.75 - 1.25 D的患者28眼(C组)或角膜散光小于0.75 D的患者23眼(D组)。在佩戴接触镜前及佩戴后至少20分钟,对所有患者进行logMAR矫正和未矫正单眼视力测量、生物显微镜检查、自动验光和角膜地形图检查。通过散光中和、视觉成功和视网膜偏差三个参数评估接触镜验配的成功率。

结果

应用软性复曲面接触镜后,A组和B组的球镜度数、柱镜和角膜曲率计散光以及视网膜偏差均显著降低(P < 0.05)。C组球镜度数和视网膜偏差降低(P < 0.05),而柱镜和角膜曲率计散光无显著变化(P > 0.05)。D组球镜度数、视网膜偏差和柱镜散光降低(P < 0.05)。角膜曲率计散光无显著变化(P > 0.05),散光中和甚至增加。

结论

使用复曲面和球面接触镜时,视力和残余球镜等效屈光度保持在可耐受范围内。在地形图检查中,球面镜未能掩盖角膜散光,而复曲面镜在低中度散光眼中导致中央中和和角膜柱镜度数降低。

相似文献

4
Visual acuity with spherical and toric soft contact lenses in low- to moderate-astigmatic eyes.
Optom Vis Sci. 2007 Oct;84(10):969-75. doi: 10.1097/OPX.0b013e318157c6dc.
6
Comparison of Toric and Spherical Orthokeratology Lenses in Patients with Astigmatism.
J Ophthalmol. 2019 Feb 20;2019:4275269. doi: 10.1155/2019/4275269. eCollection 2019.
7
Clinical evaluation of fitting toric soft contact lenses to current non-users.
Ophthalmic Physiol Opt. 2013 Mar;33(2):94-103. doi: 10.1111/opo.12028.
10
Toric intraocular lens implantation versus astigmatic keratotomy to correct astigmatism during phacoemulsification.
J Cataract Refract Surg. 2014 May;40(5):741-7. doi: 10.1016/j.jcrs.2013.10.036. Epub 2014 Mar 27.

引用本文的文献

1
Assessment of a Clinical Test for Detection of Alteration in Visual Perception Due to Astigmatism.
Clin Ophthalmol. 2024 Mar 7;18:723-733. doi: 10.2147/OPTH.S447627. eCollection 2024.
2
Simulation of the Effect of Material Properties on Soft Contact Lens On-Eye Power.
Bioengineering (Basel). 2019 Oct 9;6(4):94. doi: 10.3390/bioengineering6040094.

本文引用的文献

1
Visual acuity with spherical and toric soft contact lenses in low- to moderate-astigmatic eyes.
Optom Vis Sci. 2007 Oct;84(10):969-75. doi: 10.1097/OPX.0b013e318157c6dc.
2
Vision of low astigmats through thick and thin lathe-cut soft contact lenses.
Cont Lens Anterior Eye. 2001;24(4):153-60. doi: 10.1016/s1367-0484(01)80034-5.
3
Inefficacy of aspheric soft contact lenses for the correction of low levels of astigmatism.
Optom Vis Sci. 2005 Sep;82(9):823-8. doi: 10.1097/01.opx.0000177792.62460.58.
4
Vision with disposable toric contact lenses and daily-wear toric contact lenses.
Ophthalmic Physiol Opt. 1998 Jan;18(1):66-74. doi: 10.1016/s0275-5408(97)00040-9.
5
Videokeratography for quantitative surface analysis of used soft contact lenses.
Jpn J Ophthalmol. 1997 Jul-Aug;41(4):235-9. doi: 10.1016/s0021-5155(97)00048-8.
6
Evaluation of soft contact lens fitting characteristics.
Optom Vis Sci. 1996 Apr;73(4):247-54. doi: 10.1097/00006324-199604000-00006.
8
Topographic evaluation of toric soft contact lens correction.
CLAO J. 1994 Oct;20(4):261-5. doi: 10.1097/00140068-199410000-00014.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验