Suppr超能文献

计算机导航全膝关节置换术中的热损伤和定位器钉道感染。

Thermal damage and tracker-pin track infection in computer-navigated total knee arthroplasty.

机构信息

Department of Orthopaedic Surgery, Southland Hospital,Invercargill, New Zealand.

出版信息

J Arthroplasty. 2011 Sep;26(6):977.e21-4. doi: 10.1016/j.arth.2010.08.012. Epub 2010 Oct 14.

Abstract

Choice of pins, drills, and drilling technique can result in heat generation leading to thermal necrosis of bone. This has been reported frequently in internal as well as in external fixation. This publication is the first report of a patient having osteomyelitis of the proximal tibia due to thermal necrosis following tracker pin placement in computer-navigated total knee arthroplasty.

摘要

选择销钉、钻头和钻孔技术可能会导致热量产生,从而导致骨热坏死。这种情况在内固定和外固定中都有频繁报道。这是第一篇报道,一名患者在计算机导航全膝关节置换术中因跟踪销钉放置而导致热坏死,从而引起胫骨近端骨髓炎。