BACKGROUND

Self-expandable metallic stents (SEMS) of varying designs and materials have been developed to reduce complications, but few comparative data are available with regard to the type of stent and the stent manufacturer. We analyzed the success rates and complication rates, according to stent type (uncovered vs. covered stent) and individual stent manufacturer, in malignant colorectal obstruction.

METHODS

From November 2001 to August 2008, 103 patients were retrospectively included in this study: four types of uncovered stents in 73 patients and two types of covered stents in 30 patients. The SEMS was inserted into the obstructive site by using the through-the-scope method.

RESULTS

Technical and clinical success rates were not different between stent type or among stent manufacturers: 100 and 100% (p = ns) and 100 and 96.6% (p > 0.05), respectively, in uncovered and covered stents. Stent occlusion and migration rates were 12.3 and 3.3% (p = 0.274) and 13.7 and 16.7% (p = 0.761), respectively, in uncovered and covered stents, and 11.1, 5, and 9% (p = 0.761) and 25.9, 15, and 0% (p = 0.037) in Wallstent, Niti-S, and Bonastent uncovered stents, respectively.

CONCLUSIONS

The placement of SEMS is an effective and safe treatment for patients with malignant colorectal obstruction. Although minor differences in outcome were detected according to the type and the manufacturer of the stents, no statistically significant difference was observed, except in stent migration among the stent manufacturer.

摘要

背景

为了降低并发症的发生率,已经开发出了各种设计和材料的自膨式金属支架(SEMS),但关于支架类型和支架制造商的比较数据很少。我们分析了恶性结直肠梗阻中支架类型(uncovered 支架与 covered 支架)和支架制造商对成功率和并发症发生率的影响。

方法

回顾性纳入 2001 年 11 月至 2008 年 8 月的 103 例患者,73 例患者使用 4 种 uncovered 支架,30 例患者使用 2 种 covered 支架。通过经内镜方法将 SEMS 插入到梗阻部位。

结果

支架类型和支架制造商之间的技术和临床成功率没有差异:uncovered 支架为 100%和 100%(p = ns),covered 支架为 100%和 96.6%(p > 0.05);uncovered 支架的支架闭塞和迁移率分别为 12.3%和 3.3%(p = 0.274)和 13.7%和 16.7%(p = 0.761),covered 支架为 25.9%、15%和 0%(p = 0.037)。

结论

SEMS 的放置是治疗恶性结直肠梗阻的有效且安全的方法。尽管根据支架的类型和制造商观察到结果存在微小差异,但除支架制造商之间的支架迁移外,未观察到统计学差异。