OBJECTIVE

To evaluate the value of SPECT/CT in radionuclide arthrogram (RNA) for the assessment of mechanical loosening of hip and knee prostheses.

METHOD

A retrospective audit of 117 RNA SPECT/CTs evaluated by a single reader--40 hips, (1 hemiarthroplasty) and 77 knees (12 unicompartmental). The detection of any radiotracer within the bone/prosthetic interface was deemed positive for loosening. The operative assessment of 29 hip and 44 knee prosthetic joints was known and used as the gold standard. A subsequent blinded reassessment of the planar images was performed and compared with the SPECT/CT results for 26 of the 29 hip and 42 of the 44 knee prostheses.

RESULTS

The respective SPECT/CT versus planar results were as follows: hips--acetabular cup: sensitivity: 73 versus 0%; specificity: 71 versus 100%; positive predictive value: 62% versus indeterminate; negative predictive value: 80% versus 72% (p = 0.0044). Hips--femoral component: sensitivity: 78 versus 63%; specificity: 90 versus 94%; positive predictive value: 78 versus 83%; negative predictive value: 90 versus 85% (p = 0.2482). Knees--femoral component: sensitivity: 75 versus 17%; specificity 63 versus 97%; positive predictive value: 43 versus 67%; negative predictive value: 87 versus 74% (p = 0.0001). Knees--tibial component: sensitivity: 86 versus 63%; specificity: 86 versus 76%; positive predictive value: 55 versus 38%; negative predictive value: 97 versus 90% (p = 0.6831).

CONCLUSION

For evaluation of mechanical loosening of the hip prosthesis SPECT/CT was significantly better than planar scanning for the acetabular cup, but not for the femoral stem. For evaluation of the knee prosthesis, a significant improvement was noted using SPECT/CT for the femoral component, and although superior results were also noted for the tibial component, statistical significance was not reached. Taking into account the limitations of this retrospective audit, the value of using RNA SPECT/CT appeared to lie in the exclusion of mechanical loosening.

摘要

目的

评估单光子发射计算机断层扫描/计算机断层扫描(SPECT/CT)在放射性核素关节造影术(RNA)评估髋关节和膝关节假体机械松动中的价值。

方法

对一位读者评估的 117 例 RNA SPECT/CT 进行回顾性审核,其中包括 40 髋(1 半髋关节成形术)和 77 膝(12 个单髁)。骨/假体界面内任何放射性示踪剂的存在被认为是松动的阳性表现。29 个髋关节和 44 个膝关节假体的手术评估是已知的,并用作金标准。随后对 26 个髋关节和 42 个膝关节假体的平面图像进行了盲法重新评估,并与 SPECT/CT 结果进行了比较。

结果

各自的 SPECT/CT 与平面结果如下:髋关节——髋臼杯:灵敏度:73%比 0%;特异性:71%比 100%;阳性预测值:62%比不确定;阴性预测值:80%比 72%(p = 0.0044)。髋关节——股骨组件:灵敏度:78%比 63%;特异性:90%比 94%;阳性预测值:78%比 83%;阴性预测值:90%比 85%(p = 0.2482)。膝关节——股骨组件:灵敏度:75%比 17%;特异性:63%比 97%;阳性预测值:43%比 67%;阴性预测值:87%比 74%(p = 0.0001)。膝关节——胫骨组件:灵敏度:86%比 63%;特异性:86%比 76%;阳性预测值:55%比 38%;阴性预测值:97%比 90%(p = 0.6831)。

结论

对于髋关节假体机械松动的评估,SPECT/CT 明显优于平面扫描髋臼杯,但对股骨柄则不然。对于膝关节假体的评估,使用 SPECT/CT 对股骨组件的效果有显著改善,尽管胫骨组件的效果也更好,但未达到统计学意义。考虑到这项回顾性审核的局限性,使用 RNA SPECT/CT 的价值似乎在于排除机械松动。