Suppr超能文献

Diagnosis of peripheral arterial occlusive diseases using impedance plethysmography.

作者信息

Jindal G D, Nerurkar S N, Pedhnekar S A, Babu J P, Kelkar M D, Deshpande A K, Parulkar G B

机构信息

Electronics Division, Bhabha Atomic Research Centre, Trombay, Bombay, Maharashtra.

出版信息

J Postgrad Med. 1990 Jul;36(3):147-53.

PMID:2102915
Abstract

Impedance plethysmographic observations have been compared with arteriographic findings in 216 patients with peripheral arterial occlusive diseases. Impedance plethysmographic diagnosis in these patients was obtained by Parulkar's method without apriori knowledge of arteriographic diagnosis. But for minor discrepancy in the anatomical location of the block in few patients, impedance plethysmographic observations correlated very well with arteriographic findings. Impedance plethysmographic diagnosis was found to be correct in 312, wrong in 53, false negative in 8 limbs respectively, yielding a sensitivity of 97.5% and specificity of 98.1% of this technique.