Classen I G J, Boom J E, Suttrop W, Schmid E, Tobias B, Domier C W, Luhmann N C, Donné A J H, Jaspers R J E, de Vries P C, Park H K, Munsat T, García-Muñoz M, Schneider P A
Max Planck Institut für Plasmaphysik, 85748 Garching, Germany.
Rev Sci Instrum. 2010 Oct;81(10):10D929. doi: 10.1063/1.3483214.
The newly installed electron cyclotron emission imaging diagnostic on ASDEX Upgrade provides measurements of the 2D electron temperature dynamics with high spatial and temporal resolution. An overview of the technical and experimental properties of the system is presented. These properties are illustrated by the measurements of the edge localized mode and the reversed shear Alfvén eigenmode, showing both the advantage of having a two-dimensional (2D) measurement, as well as some of the limitations of electron cyclotron emission measurements. Furthermore, the application of singular value decomposition as a powerful tool for analyzing and filtering 2D data is presented.
在ASDEX升级装置上新安装的电子回旋辐射成像诊断设备可提供具有高空间和时间分辨率的二维电子温度动力学测量结果。本文介绍了该系统的技术和实验特性。通过对边缘局域模和反向剪切阿尔文本征模的测量来说明这些特性,展示了二维测量的优势以及电子回旋辐射测量的一些局限性。此外,还介绍了奇异值分解作为分析和过滤二维数据的强大工具的应用。