Division of Allergology, Paul-Ehrlich-Institut, 63225, Langen, Germany.
Anal Bioanal Chem. 2011 Jan;399(2):935-43. doi: 10.1007/s00216-010-4348-6. Epub 2010 Nov 3.
Even though carrot allergy is common in Europe, the amount of different allergens in carrots is still unknown due to a lack of methods for quantitative allergen measurements. The current study aimed at the development of quantitative ELISA tests for the known carrot allergens, namely Dau c 1.01, Dau c 1.02, and Dau c 4 in pure carrot extracts. Monoclonal antibodies targeting the major carrot allergen isoforms Dau c 1.01 and Dau c 1.02 were generated and combined in sandwich ELISA with rabbit antisera against Api g 1, the celery homologue of Dau c 1. A competitive ELISA for the carrot profilin Dau c 4 was based on a polyclonal rabbit antiserum. The three ELISA tests were allergen-specific and displayed detection limits between 0.4 and 6 ng allergen/ml of carrot extract. The mean coefficient of variation (CV) as a means of intraassay variability of the Dau c 1.01, Dau c 1.02 and Dau c 4 ELISA tests was 8.1%, 6.9%, and 11.9%, and the mean interassay CV 13.3%, 37.1% and 15.6%, respectively. Target recovery ranged between 93 and 113%. In conclusion, the specific, accurate and reproducible quantification of three important carrot allergens may help to identify less allergenic carrot varieties, as well as to standardize the amount of allergens in extracts used for carrot allergy diagnosis.
尽管胡萝卜过敏在欧洲很常见,但由于缺乏定量过敏原测量方法,目前仍不清楚胡萝卜中的过敏原种类。本研究旨在开发针对已知胡萝卜过敏原的定量 ELISA 检测方法,包括纯胡萝卜提取物中的 Dau c 1.01、Dau c 1.02 和 Dau c 4。针对主要胡萝卜过敏原同工型 Dau c 1.01 和 Dau c 1.02 的单克隆抗体被生成,并与针对 Api g 1(Dau c 1 的芹菜同源物)的兔抗血清在夹心 ELISA 中结合使用。用于胡萝卜丝氨酸蛋白酶 Dau c 4 的竞争性 ELISA 基于多克隆兔抗血清。三种 ELISA 检测方法均具有过敏原特异性,检测限在 0.4 至 6ng 过敏原/ml 胡萝卜提取物之间。Dau c 1.01、Dau c 1.02 和 Dau c 4 ELISA 检测方法的平均变异系数(CV)作为批内变异性的指标分别为 8.1%、6.9%和 11.9%,平均批间 CV 分别为 13.3%、37.1%和 15.6%。目标回收率在 93%至 113%之间。总之,三种重要的胡萝卜过敏原的特异性、准确性和可重复性定量检测有助于鉴定低致敏性的胡萝卜品种,并标准化用于胡萝卜过敏诊断的提取物中过敏原的含量。