Department of Ophthalmology, Aix-Marseille University, Hŏpital de la Timone Adultes, Marseille, France.
Am J Ophthalmol. 2011 Jan;151(1):29-34. doi: 10.1016/j.ajo.2010.07.016. Epub 2010 Nov 2.
To assess the use of a new polygonal trephination pattern for penetrating keratoplasty (PK) assisted by femtosecond laser.
Prospective, nonrandomized clinical study.
Sixteen eyes underwent decagonal PK. Nine had Fuchs dystrophy, 4 had pseudophakic bullous keratopathy, 1 had experienced trauma, 1 had corneal amyloidosis, and 1 had keratoconus. A Femtec (Tecnolas PerfectVision) laser was used to create decagonal penetrating cuts on both donor and recipient corneas. All patients were evaluated for uncorrected visual acuity, best spectacle-corrected visual acuity, pachymetry, topography, and endothelial cell density. Scanning electron microscopy was performed on corneal tissue after surgery.
All eyes were treated successfully without intraoperative complications. The mean follow-up ± standard deviation was 9.75 ± 3.5 months. Mean postoperative best spectacle-corrected visual acuity was 20/53, and there was a significant improvement in both uncorrected visual acuity (P = .0019) and best spectacle-corrected visual acuity (P = .001). At 6 months, mean ± standard deviation manifest astigmatism was 1.90 ± 1.20 diopters. Mean endothelial cell density was 1502 ± 458 cells/mm². Scanning electron microscopy displayed straight decagonal cut margins and minor remaining tissue bridges.
Use of the decagonal trephination profile was effective and safe to perform PK. Short-term visual results and refractive results are encouraging compared with those of conventional PK studies. Longer-term follow-up and comparative studies are necessary to determine precisely advantages the and optimal surgical settings of this technique.
评估飞秒激光辅助下新型多边形环钻在穿透性角膜移植术中的应用。
前瞻性、非随机临床研究。
16 只眼行十边形穿透性角膜移植术。其中 9 只眼为 Fuchs 营养不良,4 只眼为假性晶状体性大泡性角膜病变,1 只眼为外伤,1 只眼为角膜淀粉样变,1 只眼为圆锥角膜。使用 Femtec(Tecnolas PerfectVision)激光在供体和受体角膜上制作十边形穿透性切口。所有患者均行未矫正视力、最佳矫正视力、角膜厚度、地形图和内皮细胞密度检查。术后对角膜组织行扫描电镜检查。
所有眼均成功治疗,术中无并发症。平均随访时间为 9.75±3.5 个月。平均术后最佳矫正视力为 20/53,未矫正视力(P=.0019)和最佳矫正视力(P=.001)均有显著提高。术后 6 个月,平均(±标准差)角膜散光为 1.90±1.20 屈光度。平均内皮细胞密度为 1502±458 个细胞/mm²。扫描电镜显示十边形切割边缘笔直,少量残余组织桥。
十边形环钻在穿透性角膜移植术中使用有效且安全。与传统穿透性角膜移植术研究相比,短期视力和屈光结果令人鼓舞。需要进行更长期的随访和比较研究,以确定该技术的优势和最佳手术参数。