Huang P S, Ni J
Appl Opt. 1995 Aug 1;34(22):4976-81. doi: 10.1364/AO.34.004976.
A new development in angle measurement based on the internal-reflection effect (AMIRE) is described in which a pair of right-angle prisms is used to replace the previously used elongated critical-angle prisms, resulting in lower costs and a more compact size. Excellent linearity is achieved through careful alignment of the right-angle prisms. The measurement sensitivity and range can be selected through the use of light sources with different polarization states. Experiments with a prototype sensor demonstrated a measurement range of 1.6°, a resolution of 0.04 arcsec, and a nonlinearity error of ±0.1%. Both analytical and experimental results are presented.
本文描述了一种基于内反射效应的角度测量新进展(AMIRE),其中使用一对直角棱镜取代了先前使用的细长临界角棱镜,从而降低了成本并减小了尺寸。通过仔细对准直角棱镜实现了出色的线性度。测量灵敏度和范围可通过使用具有不同偏振态的光源来选择。对原型传感器进行的实验表明,测量范围为1.6°,分辨率为0.04弧秒,非线性误差为±0.1%。同时给出了分析和实验结果。