Suppr超能文献

[通过直接测量和间接测量获得的人体下颌骨线性形态计量学参数的比较分析]

[Comparative analysis of linear morphometric parameters of the humane mandibula obtained by direct and indirect measurement].

作者信息

Arsić Stojanka, Perić Predrag, Stojković Milos, Ilić Dragana, Stojanović Miodrag, Ajduković Zorica, Vucić Strahinja

机构信息

Medicinski fakultet, Institut za anatomiju, Nit, Srbija.

出版信息

Vojnosanit Pregl. 2010 Oct;67(10):839-46. doi: 10.2298/vsp1010839a.

Abstract

BACKGROUND/AIM: Reconstruction of lost, damaged or distorted mandibular bone presents a challenge from the functional side, as well as from the esthetic point of view. The aim of this study was to determinate potential differences between values of the basic linear moprhometric parameters (LMPs) obtained by direct and indirect manual measurement of the same humane mandibles, with accuracy testing of indirect measurement, which are routinely used in every-day clinical practice. The results are essential for defining of parametric model of the "standard mandible" and virtual modeling of the humane mandible in future researches as well as in clinical medicine.

METHODS

A total number of 12 dry bony mandibles of human adults were studied. According to the standard anatomical landmarks, 10 standard LPMs were measured on each mandible by different manual methods: directly by a sliding caliper with nonius, and indirectly using standard software on two-dimensional (2D) reconstructions of mandibular multislice computed tomography (MSCT) scans. The values obtained by the different measuring methods were matched for the same LMPs.

RESULTS

Statistically significant differences between compared LMPs values obtained by different measuring methods, appeared in the gnathio-interdental distance (Gn-IdD), as well as in the gnathio-condylar distance (Gn-CoD), bilaterally. In both parameters, significantly higher mean values (with percent of difference) were obtained by direct versus indirect measurement: Gn-IdD (21.57%; 29.2 mm vs 22.9 mm; p = 0.004); Gn-CoD left side (14.1%; 122.7 mm vs 105.4 cm; p = 0.001); Gn-CoD right side (11.87%; 124.7 mm vs 109.9 mm; p = 0.009).

CONCLUSION

According to the observed inaccuracy of indirect measurement, we recommended the use of a correction factor for calculation of both Gn-IdD and Gn-CoD real vales, in defining of parametric model of the "standard mandible" based on indirect morphometry on 2D reconstructions of mandibular MSCT scans. Additional studies with larger number of specimens and quantification of anatomical variations regarding to sex, age, dentition status and ethnic origin, additionally should increase measurement accuracy and consequently reliability of future parametric model of the human mandible.

摘要

背景/目的:下颌骨缺失、受损或变形的重建,无论从功能角度还是美学角度来看,都是一项挑战。本研究的目的是确定通过直接和间接手动测量同一人类下颌骨所获得的基本线性形态测量参数(LMPs)值之间的潜在差异,并对间接测量进行准确性测试,这些测量方法在日常临床实践中经常使用。研究结果对于定义“标准下颌骨”的参数模型以及未来研究和临床医学中人类下颌骨的虚拟建模至关重要。

方法

共研究了12具成年人类干燥下颌骨。根据标准解剖标志,通过不同的手动方法在每个下颌骨上测量10个标准LPMs:直接使用带游标卡尺测量,间接使用标准软件在多层面计算机断层扫描(MSCT)下颌骨二维(2D)重建图像上测量。对相同LMPs通过不同测量方法获得的值进行匹配。

结果

不同测量方法获得的比较LMPs值之间在统计学上有显著差异,双侧的颌间距离(Gn-IdD)以及颌髁距离(Gn-CoD)均如此。在这两个参数中,直接测量获得的平均值(及差异百分比)显著高于间接测量:Gn-IdD(21.57%;29.2毫米对22.9毫米;p = 0.004);左侧Gn-CoD(14.1%;122.7毫米对105.4厘米;p = 0.001);右侧Gn-CoD(11.87%;124.7毫米对109.9毫米;p = 0.009)。

结论

根据观察到的间接测量的不准确性,我们建议在基于下颌骨MSCT扫描二维重建的间接形态测量来定义“标准下颌骨”参数模型时,使用校正因子来计算Gn-IdD和Gn-CoD的实际值。另外,采用更多标本并对性别、年龄、牙列状况和种族起源方面的解剖变异进行量化的进一步研究,应能提高测量准确性,从而提高未来人类下颌骨参数模型的可靠性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验