College of Chemistry, Sichuan University, Chengdu 610064, China.
J Chromatogr A. 2010 Dec 10;1217(50):7840-7. doi: 10.1016/j.chroma.2010.10.077. Epub 2010 Oct 23.
The establishment of an immunoaffinity chromatography (IAC) for simultaneously selective extraction of four illegal colorants Sudan dyes (Sudan I, II, II and IV) from food samples was described. The IAC column was constructed by covalently coupling monoclonal antibody (mAb) against Sudan I to CNBr-activated Sepharose 4B and packed into a common solid phase extraction (SPE) cartridge. It was observed that IAC column was able to separately capture Sudan I, II, III and IV with maximum capacity of 295, 156, 184 and 173ng, respectively. The extraction conditions including loading, washing and eluting solutions were carefully optimized. Under optimal conditions, the extraction recoveries of the IAC column for Sudan I-IV at two different spiked concentrations were within 95.3-106.9%. After 50 times repeated usage, 64% of the maximum capacity was still remained. Six food samples randomly collected from local supermarket without spiking Sudan dyes were extracted with IAC column and detected by high performance liquid chromatography (HPLC). It was found that there was no detectable Sudan II, III and IV in all six food samples, but Sudan I with the content of 2.7-134.5ngg(-1) was detected in three food samples. To further verify the extraction efficiency, other three negative samples were spiked with Sudan I-IV at the concentrations of 20ngg(-1) and 50ngg(-1), which were then extracted with IAC column. The extraction recoveries and relative standard deviation (RSD) were 68.6-96.0% and 4.8-15.2%, respectively, demonstrating the feasibility of the prepared IAC column for Sudan dyes extraction.
建立了一种免疫亲和色谱法(IAC),可同时从食品样品中选择性提取四种非法着色剂苏丹染料(苏丹 I、II、III 和 IV)。IAC 柱通过将针对苏丹 I 的单克隆抗体(mAb)共价偶联到 CNBr 活化的 Sepharose 4B 上,并填充到常见的固相萃取(SPE)小柱中而构建。结果表明,IAC 柱能够分别捕获苏丹 I、II、III 和 IV,最大容量分别为 295、156、184 和 173ng。仔细优化了包括加载、洗涤和洗脱溶液在内的提取条件。在最佳条件下,IAC 柱对苏丹 I-IV 的提取回收率在两个不同的加标浓度范围内为 95.3-106.9%。经过 50 次重复使用后,仍保持 64%的最大容量。用 IAC 柱从当地超市随机采集的 6 份未加标苏丹染料的食品样品进行提取,并通过高效液相色谱(HPLC)进行检测。结果发现,在所有 6 份食品样品中均未检测到苏丹 II、III 和 IV,但在 3 份食品样品中检测到苏丹 I,含量为 2.7-134.5ngg(-1)。为了进一步验证提取效率,将另外 3 个阴性样品分别用苏丹 I-IV 在 20ngg(-1)和 50ngg(-1)的浓度下加标,然后用 IAC 柱进行提取。提取回收率和相对标准偏差(RSD)分别为 68.6-96.0%和 4.8-15.2%,表明制备的 IAC 柱用于苏丹染料提取是可行的。