Suppr超能文献

不同水平的气道正压对冠状动脉旁路移植术后呼吸模式和心率变异性的影响。

Effects of different levels of positive airway pressure on breathing pattern and heart rate variability after coronary artery bypass grafting surgery.

机构信息

Departamento de Fisioterapia, Universidade Federal de São Carlos, SP, Brasil.

出版信息

Braz J Med Biol Res. 2011 Jan;44(1):38-45. doi: 10.1590/s0100-879x2010007500129. Epub 2010 Nov 19.

Abstract

The application of continuous positive airway pressure (CPAP) produces important hemodynamic alterations, which can influence breathing pattern (BP) and heart rate variability (HRV). The aim of this study was to evaluate the effects of different levels of CPAP on postoperative BP and HRV after coronary artery bypass grafting (CABG) surgery and the impact of CABG surgery on these variables. Eighteen patients undergoing CABG were evaluated postoperatively during spontaneous breathing (SB) and application of four levels of CPAP applied in random order: sham (3 cmH₂O), 5 cmH₂O, 8 cmH₂O, and 12 cmH₂O. HRV was analyzed in time and frequency domains and by nonlinear methods and BP was analyzed in different variables (breathing frequency, inspiratory tidal volume, inspiratory and expiratory time, total breath time, fractional inspiratory time, percent rib cage inspiratory contribution to tidal volume, phase relation during inspiration, phase relation during expiration). There was significant postoperative impairment in HRV and BP after CABG surgery compared to the preoperative period and improvement of DFAα1, DFAα2 and SD2 indexes, and ventilatory variables during postoperative CPAP application, with a greater effect when 8 and 12 cmH₂O were applied. A positive correlation (P < 0.05 and r = 0.64; Spearman) was found between DFAα1 and inspiratory time to the delta of 12 cmH₂O and SB of HRV and respiratory values. Acute application of CPAP was able to alter cardiac autonomic nervous system control and BP of patients undergoing CABG surgery and 8 and 12 cmH₂O of CPAP provided the best performance of pulmonary and cardiac autonomic functions.

摘要

持续气道正压通气(CPAP)的应用会产生重要的血液动力学改变,这可能会影响呼吸模式(BP)和心率变异性(HRV)。本研究的目的是评估不同水平的 CPAP 在冠状动脉旁路移植术(CABG)后对术后血压和 HRV 的影响,以及 CABG 手术对这些变量的影响。18 例接受 CABG 的患者在自主呼吸(SB)和随机应用 4 个水平的 CPAP 期间进行术后评估:假(3cmH₂O)、5cmH₂O、8cmH₂O 和 12cmH₂O。HRV 分别在时间和频率域以及非线性方法中进行分析,血压在不同变量(呼吸频率、吸气潮气量、吸气和呼气时间、总呼吸时间、吸气分数时间、肋骨吸气潮气量的百分比贡献、吸气期间的相位关系、呼气期间的相位关系)中进行分析。与术前相比,CABG 手术后 HRV 和血压明显受损,在术后 CPAP 应用期间,DFAα1、DFAα2 和 SD2 指数以及通气变量得到改善,当应用 8 和 12cmH₂O 时效果更大。在 DFAα1 和 12cmH₂O 的 delta 与 SB 的 HRV 和呼吸值的吸气时间之间存在正相关(P<0.05 和 r=0.64;Spearman)。急性应用 CPAP 能够改变接受 CABG 手术的患者的心脏自主神经系统控制和血压,8 和 12cmH₂O 的 CPAP 可提供最佳的肺和心脏自主功能表现。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验