Abstract

Determination of dose modification factor greatly facilitates the introduction of clinically proven neutron therapy schedules at new installations. We have compared the biological performance of the p(66)+Be neutron facility at Faure, South Africa, with the established p(65)+Be installation at Louvain-la-Neuve, Belgium. Filtration, D gamma/DT, dose rate and HVT 5/15 for the Louvain and Faure beam are: 2 cm, 2.5 cm polyethylene; 3%, 5%; 0.2 Gy/min, 0.4 Gy/min; and 20 cm and 19 cm respectively. Dosimetry was done in A-150 plastic. Irradiation of BALB/C mice was carried on according to the dose accumulation method in a perspex phantom at 5 cm depth and at an SSD of 150 cm at a field size of 28 X 28 cm2. Sections of the jejunum were prepared at each centre and analyzed by both. The RBE of the Faure beam determined at a survival level of 50 crypts ranged from 1.64 to 1.69. The dose modification factor RBE of the Louvain beam given by Beauduin et al. was 1.61 +/- 0.14. The dose modification factor of the Faure beam relative to the Louvain beam is thus 1.03 +/- 0.13 which could be expected from the similarity of the physical characteristics. Independent RBE measurements in a variety of systems also suggest similar biological properties. The depth variation of the RBE was found to be 4% (mouse gut) using 3 cm polyethylene filter over the depth range of 2.5 to 13.5 cm. This is in agreement with microdosimetry measurements using polyethylene filters of various thicknesses and with V79 measurements reported by Slabbert et al.

摘要

剂量修正因子的确定极大地促进了在新设施中引入经过临床验证的中子治疗方案。我们已将南非福尔的p(66)+Be中子设施的生物学性能与比利时鲁汶新堡已有的p(65)+Be设施进行了比较。鲁汶和福尔束流的过滤、Dγ/DT、剂量率和HVT 5/15分别为:2 cm,2.5 cm聚乙烯;3%,5%;0.2 Gy/分钟,0.4 Gy/分钟;以及分别为20 cm和19 cm。剂量测定在A-150塑料中进行。按照剂量累积方法,在有机玻璃模体中于5 cm深度、150 cm源皮距和28×28 cm2的射野尺寸下对BALB/C小鼠进行照射。在每个中心制备空肠切片并进行分析。在50个隐窝存活水平下测定的福尔束流的RBE范围为1.64至1.69。博杜安等人给出的鲁汶束流的剂量修正因子RBE为1.61±0.14。因此,福尔束流相对于鲁汶束流的剂量修正因子为1.03±0.13,这可从物理特性的相似性预期得到。在各种系统中的独立RBE测量也表明具有相似的生物学特性。发现在2.5至13.5 cm的深度范围内使用3 cm聚乙烯滤过器时,RBE的深度变化为4%(小鼠肠道)。这与使用各种厚度聚乙烯滤过器的微剂量测定结果以及斯拉伯特等人报告的V79测量结果一致。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验