Department of Orthopaedics, University of Virginia, Charlottesville, VA 22908, USA.
J Arthroplasty. 2011 Sep;26(6):978.e5-8. doi: 10.1016/j.arth.2010.10.002. Epub 2010 Dec 4.
Anterior iliopsoas impingement is a recognized cause of persistent groin pain after total hip arthroplasty. We report 3 patients with failed total hip arthroplasties resulting from anterior iliopsoas and capsular impingement secondary to a metal femoral ball with a diameter larger than the native femoral head. All patients had the same implant design. Resolution of symptoms occurred in all patients after revision surgery. To our knowledge, this is the first report of this potential failure mechanism with these large-diameter implant designs and should be considered in the appropriate clinical scenario.
髂腰肌撞击症是全髋关节置换术后持续性腹股沟疼痛的公认原因。我们报告了 3 例因金属股骨球直径大于原生股骨头而导致的前髂腰肌和囊状撞击引起的全髋关节置换失败的患者。所有患者均采用相同的植入物设计。翻修手术后,所有患者的症状均得到缓解。据我们所知,这是首次报道这种大直径植入物设计的潜在失效机制,在适当的临床情况下应予以考虑。