This study describes the changes in hip and pelvic kinematics in 19 trans-femoral amputees, who were treated with an osseointegrated trans-femoral prosthesis. Patients were studied with 3-dimensional gait analysis, walking with socket prosthesis within two days before the osseointergration procedure. The post-operative gait analysis was carried out at the 2 year follow-up visit. Fifty-seven; age-, side- and gender-matched healthy subjects served as controls. Post-operative data showed that patients who had an osseointegrated transfemoral prosthesis increased their hip extension by 7.3° (p=0.007), changing from -2.6° (range -13.4° to 10.7°) to -9.9° (range -29.4° to 5°). Moreover, the pre-operative anterior pelvic tilt was reduced by 4.0° (p=0.016), changing from 21.7° (range 11.9-34.8°) to 17.7° (range 5.5-25.7°). Values for hip extension and pelvic tilt changed toward those of controls. These results confirm that patients treated with osseointegrated trans-femoral prosthesis encounter significant changes of their kinematic pattern in terms of hip extension and anterior pelvic tilt. Even though the changes were moderate they may, in the long-term have a positive influence on low-back biomechanics and could contribute to reducing the risk of further problems with low back pain.
本研究描述了 19 名接受骨整合式股骨假体治疗的股骨截肢患者髋关节和骨盆运动学的变化。患者在接受骨整合手术前两天使用socket 假体进行三维步态分析,术后 2 年进行步态分析。57 名年龄、性别和侧别匹配的健康受试者作为对照组。术后数据显示,接受骨整合式股骨假体的患者髋关节伸展增加了 7.3°(p=0.007),从-2.6°(范围-13.4°至 10.7°)变为-9.9°(范围-29.4°至 5°)。此外,术前骨盆前倾减少了 4.0°(p=0.016),从 21.7°(范围 11.9-34.8°)变为 17.7°(范围 5.5-25.7°)。髋关节伸展和骨盆前倾的数值向对照组的数值变化。这些结果证实,接受骨整合式股骨假体治疗的患者在髋关节伸展和骨盆前倾方面遇到了明显的运动模式变化。尽管变化幅度适中,但它们可能会对下背部生物力学产生长期积极影响,并有助于降低进一步出现下背部疼痛问题的风险。