用于碳离子治疗计划系统的局部效应模型可靠性分析。

Analysis of the reliability of the local effect model for the use in carbon ion treatment planning systems.

作者信息

Russo G, Attili A, Bourhaleb F, Marchetto F, Peroni C, Schmitt E, Bertrand D

机构信息

Istituto Nazionale di Fisica Nucleare sezione di Torino, Via Pietro Giuria 1, 10125 Torino, Italy.

出版信息

Radiat Prot Dosimetry. 2011 Feb;143(2-4):497-502. doi: 10.1093/rpd/ncq407. Epub 2010 Dec 3.

Abstract

In radiotherapy with carbon ions, biological effects of treatments have to be predicted. For this purpose, one of the most used models is the local effect model (LEM) developed at the Gesellschaft für Schwerionenforschung (GSI), Germany. At the Istituto Nazionale di Fisica Nucleare, Italy, the reliability of the last published version of LEM (LEM III) in reproducing radiobiological data has been checked under both monoenergetic and spread-out Bragg peak (SOBP) carbon-ion irradiation. The reproduction of the monoenergetic measurements with the LEM was rather successful for some cell lines, while it failed for the less-radioresistant ones. The SOBP experimental trend was predicted by the LEM, but a large shift between model curves and measured points was observed.

摘要

在碳离子放射治疗中,必须预测治疗的生物学效应。为此,最常用的模型之一是由德国重离子研究中心(GSI)开发的局部效应模型(LEM)。在意大利国家核物理研究所,已在单能和扩展布拉格峰(SOBP)碳离子照射下检查了LEM的最新发布版本(LEM III)在再现放射生物学数据方面的可靠性。对于某些细胞系,用LEM对单能测量的再现相当成功,而对于放射抗性较低的细胞系则失败了。LEM预测了SOBP实验趋势,但观察到模型曲线与测量点之间存在较大偏差。