Suppr超能文献

使用法尔高能中子设施的临床前研究:猪皮肤对分次剂量快中子(66 MeVp——铍)的反应。

Preclinical studies with the Faure high energy neutron facility: response of pig skin to fractionated doses of fast neutrons (66 MeVp----Be).

作者信息

Blekkenhorst G, Hendrikse A, Kent C, Jones D, van den Aardweg G J

机构信息

Department of Radiotherapy, University of Cape Town/Groote Schuur Hospital, South Africa.

出版信息

Radiother Oncol. 1990 Jun;18(2):147-54. doi: 10.1016/0167-8140(90)90140-r.

Abstract

The early and late responses of pig skin to fractionated doses of both unfiltered and filtered (i.e. hardened) neutrons using the Faure neutron therapy facility (66 MeVp----Be) were determined and compared with those following fractionated doses with 60Co gamma-rays. Dose-effect curves for the quantal responses of moist desquamation (early epithelial response) and dermal necrosis (late response) were fitted by probit analysis and ED50 values obtained. For a neutron fractionation scheme comprised of 12 fractions in 26 days, and using an unfiltered beam, the ED50 values for moist desquamation and dermal necrosis were 18.67 +/- 2.22 and 22.25 +/- 0.48 Gy, respectively, whereas in the case of the filtered beam, the corresponding ED50 values were 24.78 +/- 1.44 and 23.30 +/- 0.47 Gy. In order to provide a comparison, the values for 24 fractions of 60Co gamma-rays given in 39 days (a clinical protocol used in the Groote Schuur Hospital) were 74.02 +/- 2.92 and 66.72 +/- 1.93 Gy for moist desquamation and dermal necrosis, respectively. For the unfiltered beam, values for the comparative biological effectiveness (CBE) were 3.96 and 3.00 for the early and late skin response, respectively. The corresponding CBE values were for the filtered beam 2.99 and 2.86. These results for the Faure neutron therapy facility can be extrapolated to the human situation with a high degree of confidence, so that the neutron dose which would yield acceptable skin damage in patients may be determined using the data presented here.

摘要

利用法尔中子治疗设备(66 MeVp----铍),测定了猪皮肤对未过滤和过滤(即硬化)的分次中子剂量的早期和晚期反应,并将其与60钴γ射线分次剂量后的反应进行比较。通过概率分析拟合了湿性脱屑(早期上皮反应)和皮肤坏死(晚期反应)的定量反应剂量效应曲线,并获得了ED50值。对于在26天内分12次的中子分次照射方案,使用未过滤束流时,湿性脱屑和皮肤坏死的ED50值分别为18.67±2.22和22.25±0.48 Gy,而对于过滤束流,相应的ED50值为24.78±1.44和23.30±0.47 Gy。为了进行比较,在39天内给予24次60钴γ射线(格罗特舒尔医院使用的临床方案)时,湿性脱屑和皮肤坏死的值分别为74.02±2.92和66.72±1.93 Gy。对于未过滤束流,早期和晚期皮肤反应的相对生物效能(CBE)值分别为3.96和3.00。过滤束流的相应CBE值为2.99和2.86。法尔中子治疗设备的这些结果可以高度可靠地外推到人体情况,从而可以使用此处给出的数据确定在患者中产生可接受皮肤损伤的中子剂量。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验