Suppr超能文献

使用IOL Master测量准分子原位角膜磨镶术前和术后的眼轴长度:一项初步研究。

Axial eye length measurements pre-and post-laser-assisted in situ keratomileusis using the IOL Master: a pilot study.

作者信息

Chalkiadakis Spyridon E, Amariotakis Georgios A, Parikakis Efstratios A, Peponis Vasileios G

机构信息

Athens Eye Hospital, 2nd Eye Clinic, Athens, Greece.

出版信息

Clin Ophthalmol. 2010 Nov 8;4:1267-9. doi: 10.2147/OPTH.S14332.

Abstract

PURPOSE

A preliminary study in order to test the accuracy of the IOL Master in detecting axial eye length changes after laser-assisted in situ keratomileusis and to correlate the findings with the theoretical ablation depth.

METHODS

Pre-and postoperative axial eye length measurements were performed in 10 consecutive eyes that underwent laser-assisted in situ keratomileusis with the Alcon Ladar Vision excimer laser to treat myopic refractive errors ranging from -2.50 to -8.00 diopters of spherical equivalent (mean: -5.23 ± 1.30 D).

RESULTS

The preoperative axial eye length measurements ranged from 24.53 mm to 27.78 mm (mean: 25.80 ± 1.01 mm) and from 24.57 mm to 27.57 mm (mean: 25.68 ± 0.93 mm) 1 month after the operation. Preoperative and 1-month postoperative data showed a statistically significant difference (P < 0.05).

CONCLUSIONS

The IOL Master showed a decrease in the axial eye length measurements that was bigger than the theoretical ablation depth and did not correlate well with it. Such data need to be confirmed by a larger cohort of patients.

摘要

目的

进行一项初步研究,以测试IOL Master在检测准分子原位角膜磨镶术后眼轴长度变化方面的准确性,并将研究结果与理论消融深度相关联。

方法

对连续10只接受爱尔康LADAR VISION准分子激光准分子原位角膜磨镶术治疗等效球镜度为-2.50至-8.00屈光度(平均:-5.23±1.30 D)近视屈光不正的眼睛进行术前和术后眼轴长度测量。

结果

术前眼轴长度测量范围为24.53 mm至27.78 mm(平均:25.80±1.01 mm),术后1个月为24.57 mm至27.57 mm(平均:25.68±0.93 mm)。术前和术后1个月的数据显示出统计学上的显著差异(P<0.05)。

结论

IOL Master显示眼轴长度测量值的下降幅度大于理论消融深度,且两者相关性不佳。此类数据需要更多患者队列进行证实。

相似文献

3
Optical biometry before and after excimer laser epithelial keratomileusis (LASEK) for myopia.
Eur J Ophthalmol. 2003 Apr;13(3):257-9. doi: 10.1177/112067210301300303.
5
Assessment of axial length before and after myopic LASIK with the IOLMaster.IOLMaster 测量近视 LASIK 前后的眼轴长度评估。
J Refract Surg. 2013 Dec;29(12):838-41. doi: 10.3928/1081597X-20130924-01. Epub 2013 Oct 4.

本文引用的文献

1
Axial eye length evaluation before and after myopic photorefractive keratectomy.
J Refract Surg. 2005 May-Jun;21(3):281-7. doi: 10.3928/1081-597X-20050501-12.
2
The organization of collagen in the corneal stroma.角膜基质中胶原蛋白的组织结构。
Exp Eye Res. 2004 Mar;78(3):503-12. doi: 10.1016/j.exer.2003.07.003.
3
The structure and transparency of the cornea.角膜的结构与透明度。
J Physiol. 1957 Apr 30;136(2):263-86. doi: 10.1113/jphysiol.1957.sp005758.
4
Optical biometry before and after excimer laser epithelial keratomileusis (LASEK) for myopia.
Eur J Ophthalmol. 2003 Apr;13(3):257-9. doi: 10.1177/112067210301300303.
7
The cornea is not a piece of plastic.角膜不是一块塑料。
J Refract Surg. 2000 Jul-Aug;16(4):407-13. doi: 10.3928/1081-597X-20000701-03.
8
Keratophakia and keratomileusis--clinical results.角膜磨镶术和角膜切削术——临床结果
Ophthalmology. 1981 Aug;88(8):709-15. doi: 10.1016/s0161-6420(81)34958-6.
9
Keratomileusis.角膜磨镶术
Int Surg. 1967 Aug;48(2):103-17.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验