Institute for Laboratory Animal Science and Experimental Surgery, RWTH-Aachen University, Pauwelsstrasse 30, Aachen, Germany.
Ann Biomed Eng. 2011 Mar;39(3):1051-9. doi: 10.1007/s10439-010-0228-7. Epub 2010 Dec 16.
To assess the effect of the perfusion pressure (PP) during machine perfusion (MP) on the preservation quality of kidney grafts, we compared mean PPs of 25 and 30 mmHg using a porcine autotransplantation model. After assessment of the microcirculation, animals underwent left nephrectomy. Thereafter, kidneys were washed out followed by 20 h of MP at 25 mmHg (MP25, n = 7) or 30 mmHg (MP30, n = 7) using a novel MP system for hypothermic pulsatile perfusion. After MP preservation, the contralateral kidneys were removed and the preserved kidneys heterotopically autotransplanted. Ten minutes after reperfusion, the microcirculation was reassessed. Seven days posttransplant, animals were euthanized and the kidney grafts removed for histological analysis. MP using a mean PP of 25 mmHg resulted in higher capillary blood flow after reperfusion. In the MP30 group, 6 out of 7 animals survived, whereas in the MP25 group all animals survived. Overall, improvement in recovery of renal function and a better preservation of structural integrity were seen in the MP25 group compared to the MP30 group. Using a novel system for hypothermic MP, a mean PP of 25 mmHg is preferred over a mean PP of 30 mmHg.
为了评估机器灌注(MP)期间的灌注压(PP)对肾移植物保存质量的影响,我们使用猪自体移植模型比较了 25mmHg 和 30mmHg 的平均 PP。在评估微循环后,动物进行左肾切除术。此后,用一种新的低温搏动灌注 MP 系统对肾脏进行灌洗,然后在 25mmHg(MP25,n=7)或 30mmHg(MP30,n=7)下进行 20 小时的 MP。MP 保存后,切除对侧肾脏并将保存的肾脏异位自体移植。再灌注后 10 分钟再次评估微循环。移植后 7 天,处死动物并取出肾移植物进行组织学分析。使用平均 PP 为 25mmHg 的 MP 可在再灌注后增加毛细血管血流。在 MP30 组中,7 只动物中有 6 只存活,而在 MP25 组中所有动物均存活。总的来说,与 MP30 组相比,MP25 组的肾功能恢复和结构完整性保存均有所改善。使用一种新的低温 MP 系统,平均 PP 为 25mmHg 优于平均 PP 为 30mmHg。