Suppr超能文献

[REZ-I型人工耳蜗植入对成年患者残余听力的影响]

[Effect of REZ-I cochlear implantation on residual hearing in adult patients].

作者信息

Tao Duo-duo, Chen Bing, Wang Zheng-min, Chi Fang-lu, Li Hua-wei

机构信息

Department of Otology and Skull Base Surgery, Fudan University, Shanghai 200031, China.

出版信息

Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi. 2010 Oct;45(10):824-9.

Abstract

OBJECTIVE

To evaluate the effect of cochlear implantation with REZ-I straight electrodes on residual hearing of postlingually deafened adults, and to explore the audiologically safety and injury characteristics of cochlear implantation.

METHODS

Sixteen unilateral REZ-I (22 channels) cochlear implantation recipients from September 2009 to December 2009 were picked out. Their pre-and post-implantation audiometry data including pure-tone audiometry (PTA), auditory steady-state responses (ASSR), auditory brainstem responses (ABR) and distortion product otoacoustic emissions (DPOAE) were retrospectively analyzed, in order to compare the change between pre- and post-implantation residual hearing.

RESULTS

Among the 12 recipients who had some measurable residual hearing before implantation, 5 (41.6%) patients had conserved some measurable hearing but the other 7 (58.4%) recipients had lost all measurable hearing after implantation on the implanted side. The implanted ears had an average PTA threshold drop of 9.5 dB HL and a statistically significant difference between pre- and post-implantation (P < 0.05) PTA thresholds in the frequencies of 250 Hz, 500 Hz, 1000 Hz, 2000 Hz and 4000 Hz. Compared to non-implanted ears, the drop in 500 Hz and 1kHz had a statistically significant difference between pre- and post-implantation PTA thresholds (P < 0.05). The ASSR residual hearing threshold elevation were statistically significant (P < 0.05) between pre- and post-implantation ASSR at 250 Hz and 500 Hz on the implanted side, while the The ASSR residual hearing threshold elevation were statistically significant (P < 0.05) at 500 Hz when compared to non-implanted side. The difference of residual hearing between pre- and post-implantation was not statistically significant for both DPOAE and ABR.

CONCLUSION

There will be a certain degree of damage to residual hearing of the implanted side following REZ-I cochlear implantation.

摘要

目的

评估使用REZ-I直电极进行人工耳蜗植入对语后聋成人残余听力的影响,并探讨人工耳蜗植入的听力学安全性及损伤特点。

方法

选取2009年9月至2009年12月期间16名单侧接受REZ-I(22通道)人工耳蜗植入的患者。回顾性分析其植入前后的听力测试数据,包括纯音听力测试(PTA)、听觉稳态反应(ASSR)、听觉脑干反应(ABR)和畸变产物耳声发射(DPOAE),以比较植入前后残余听力的变化。

结果

在植入前有可测量残余听力的12名患者中,5名(41.6%)患者保留了一些可测量的听力,但另外7名(58.4%)患者在植入后植入侧失去了所有可测量的听力。植入耳的平均PTA阈值下降了9.5 dB HL,在250 Hz、500 Hz、1000 Hz、2000 Hz和4000 Hz频率下,植入前后的PTA阈值差异有统计学意义(P < 0.05)。与未植入耳相比,500 Hz和1kHz频率下植入前后的PTA阈值下降差异有统计学意义(P < 0.05)。植入侧在250 Hz和500 Hz频率下,植入前后ASSR残余听力阈值升高有统计学意义(P < 0.05),而与未植入侧相比,500 Hz频率下ASSR残余听力阈值升高有统计学意义(P < 0.05)。DPOAE和ABR植入前后的残余听力差异无统计学意义。

结论

REZ-I人工耳蜗植入后,植入侧的残余听力会受到一定程度的损害。