A method for visualizing high-density porous polyethylene (medpor, porex) with computed tomographic scanning.

作者信息

Vendemia Nicholas, Chao Jerry, Ivanidze Jana, Sanelli Pina, Spinelli Henry M

机构信息

New York Presbyterian Hospital, Weill-Cornell Medical Center, New York, New York, USA.

出版信息

J Craniofac Surg. 2011 Jan;22(1):73-6. doi: 10.1097/SCS.0b013e3181f6f5fc.

Abstract

BACKGROUND

Medpor (Porex Surgical, Inc, Newnan, GA) is composed of porous polyethylene and is commonly used in craniofacial reconstruction. When complications such as seroma or abscess formation arise, diagnostic modalities are limited because Medpor is radiolucent on conventional radiologic studies. This poses a problem in situations where imaging is necessary to distinguish the implant from surrounding tissues.

OBJECTIVE

To present a clinically useful method for imaging Medpor with conventional computed tomographic (CT) scanning.

MATERIALS AND METHODS

Eleven patients (12 total implants) who have undergone reconstructive surgery with Medpor were included in the study. A retrospective review of CT scans done between 1 and 16 months postoperatively was performed using 3 distinct CT window settings. Measurements of implant dimensions and Hounsfield units were recorded and qualitatively assessed.

RESULTS

Of the 3 distinct window settings studied, namely, "bone" (W1100/L450), "soft tissue"; (W500/L50), and "implant" (W800/L200), the implant window proved the most ideal, allowing the investigators to visualize and evaluate Medpor in all cases. Qualitative analysis revealed that Medpor implants were able to be distinguished from surrounding tissue in both the implant and soft tissue windows, with a density falling between that of fat and fluid. In 1 case, Medpor could not be visualized in the soft tissue window, although it could be visualized in the implant window. Quantitative analysis demonstrated a mean (SD) density of -38.7 (7.4) Hounsfield units.

CONCLUSIONS

Medpor may be optimally visualized on conventional CT scans using the implant window settings W800/L200, which can aid in imaging Medpor and diagnosing implant-related complications.

摘要

相似文献

1
A method for visualizing high-density porous polyethylene (medpor, porex) with computed tomographic scanning.
J Craniofac Surg. 2011 Jan;22(1):73-6. doi: 10.1097/SCS.0b013e3181f6f5fc.
4
Imaging of porous polyethylene implant by using multidetector spiral computed tomography.
J Craniofac Surg. 2008 Jan;19(1):156-8. doi: 10.1097/scs.0b013e31815c8a3a.
9

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验